Manafacture: Philips
File size: 2.91 mb
File name: hx6732_02_dfu_dan.pdf
|
manual abstract
To activate Easy-start: Press and hold the on/off button for 2 seconds.You hear 2 beeps to indicate that the Easy-start feature has been activated. Note: Use of the Easy-start feature beyond the initial ramp-up period is not recommended and reduces the effectiveness of the Sonicare toothbrush in removing plaque. Smartimer The Smartimer indicates that your brushing cycle is complete by automatically switching off the toothbrush at the end of the brushing cycle. Dental professionals recommend brushing no less than 2 minutes twice a day. If you want to pause or stop brushing during the 2-minute brushing cycle, press and hold the on/off button for 2 seconds. Press the on/off button again and the Smartimer picks up where you left off. The Smartimer automatically resets to the beginning of a 2-minute cycle if: you stop brushing for 30 seconds or longer. you put the handle in the charger. -- - - -- 4235.020.2529.2.indd 8 22-09-2008 10:30:12 1243 ENGLISH 9 Quadpacer (select models) -The Quadpacer is an interval timer that has a short beep and pause to remind you to brush the 4 sections of your mouth evenly and thoroughly. -When you use the two-minute Clean or Sensitive mode, you hear a short beep and a pause in brushing action at 30, 60 and 90 seconds. -When you use the Clean and White mode, you hear and feel a change in the brush head sound and motion after 2 minutes of Clean mode. Then move the brush head to the visible upper front teeth and brush them for 15 seconds. At the final beep and pause, move to the visible lower front teeth and brush them for 15 seconds. Cord wrap facility (specific types only) If your Sonicare type includes the deluxe charger cover and base, the travel charger is pre-installed inside the cover. If you want to shorten the mains cord, you can store excess cord in the cord wrap facility in the charger base. 1 To separate the charger cover from the charger base, press the two grey snap bars on the charger base and pull the white charger cover upwards. 2 Wrap excess mains cord around the grey charger base as shown in the picture. Make sure you wrap the cord on the inside of the two snap levers. 3 4 When you have stored the excess cord, guide the mains cord through the small groove in the rear of the grey charger base. To reattach the charger cover, press it down over the charger base until it snaps into place. Tip: For extra convenience during travel, you can remove the travel charger and use it without the charger cover and charger base. 4235.020.2529.2.indd 9 22-09-2008 10:30:13 10 ENGLISH Cleaning Do not clean brush heads, the handle, the charger or the charger covers in the dishwasher. Toothbrush handle 1 Remove the brush head and rinse the metal shaft area with warm water. Do not push on the rubber seal on the metal shaft with sharp objects, as this may cause damage. 2 Wipe the entire surface of the handle with a damp cloth. Brush head 1 Rinse the brush head and bristles after each use. 2 Remove the brush head from the handle and rinse the brush head connection at least once a week with warm water. Charger 1 Unplug the charger before you clean it. 2 Wipe the surface of the charger with a damp cloth. Storage If you are not going to use the appliance for a long time, unplug it, clean it and store it in a cool and dry place away from direct sunlight.You can use the cord wrap facility (specific types only) to store the mains cord in an organised way. You can store brush heads on the pegs at the back of the charger. Replacement Brush head Replace Sonicare brush heads every 3 months to achieve optimal results. Use only Sonicare ProResults replacement brush heads. - - - - 4235.020.2529.2.indd 10 22-09-2008 10:30:14 ENGLISH 11 Disposal Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment. The built-in rechargeable battery contains substances that may pollute the environment. Always remove the battery before you discard and hand in the appliance at an official collection point. Dispose of the battery at an official collection point for batteries. If you have trouble removing the battery, you can also take the appliance to a Philips service centre.The staff of this centre will remove the battery for you and will dispose of it in an environmentally safe way. Removing the rechargeable battery Please note that this process is not reversible. 1 To deplete the rechargeable battery of any charge, remove the handle from the charger, switch on the Sonicare and let it run until it stops. Repeat this step until you can no longer switch on the Sonicare. 2 Insert a flathead (standard) screwdriver into the slot located at the bottom of the handle and turn it anticlockwise to release the bottom cap. 3 Hold the handle upside down and push down on the shaft to release the internal components of the handle. 4 Insert the screwdriver under the circuit board, next to t...
Other models in this manual:Electric Toothbrushs - HX6712 (2.91 mb)
Electric Toothbrushs - HX6782 (2.91 mb)
Electric Toothbrushs - HX6780 (2.91 mb)
Electric Toothbrushs - HX6712/75 (2.91 mb)