|
manual abstract
After this period the fan switches off automatically. Lighting: .. The light can be switched on at any time, even though the fan is switched on. Remote control: The remote control is set up by the manufacturer. If the remote control is not controlling motor o light nearby the cooker hood, please do the following. Set up of the remote control. Keep pressing the “+” button of the remote control and then connect the cooker hood, to confirm that the remote control has been recognized a long beep is issued. If you do not hear the acoustic signal within 30 seconds, please repeat the steps as described. Functions of the remote control. The +, -, and Light Push button have the same functions as on the controls of the hood. The : Push button has the same function as the * . Light It switches motor off Timer It switches motor on and increases the speeds Speeds Indicator It decreases the speeds Interval Function: A specific function of this appliance is the Interval Function which consists in activating the motor in automatic way 10 minutes each hour at the speed flashing in the display. This function can be activated on the control of the hood or by remote control. Interval Function by controls: .. Keep pressing at the same time the O and + push buttons, then release them: the display will show the 1; .. Keep pressing at the same time the + push button, the display will show the following for the speeds of the motor 2>3>1>2 …; .. Keep pressing at the same time the O and + push buttons to confirm the speed for the motor you wish for the interval function. Interval Function by remote control: .. Keep pressing the : push button. The display will show 1; .. Keep pressing the + push button, the display will show the following for the speeds of the motor 2>3>1>2 …; .. Press the push button to confirm the speed of the motor for the interval function. When you are in the setting phase, if the interval function shown is not confirmed within some seconds, then you get out of the setting mode for the interval function. By pressing any push button, light excluded, the interval function is excluded. The remote control has a battery – When the battery is exhausted you need to: 1. loosen the 2 screws on the rear part and remove the cover. 2. take the battery out and replace it with one with the same characteristics. 3. Close the cover again and tighten the screws. Follow National norms for waste disposal of exhausted batteries. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of catching fire increase, but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: When the grease filters are saturated flashes. If you switch the hood off, then the acoustic signal is removed. The grease filters should be cleaned straight away. Cleaning the metal grease filters: .. In normal operation (1-2 hours daily) the metal grease filter must be cleaned 1x a month. .. The filters can be cleaned in a dish washer. It is however possible that they become slightly discoloured. The filters must be placed loosely and NOT wedged in the dishwasher Important: Metal filters that are saturared with grease should not be washed together with other dishes. .. When clearing the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and installing the metal grease filters: Attention: the halogen bulbs must be switched off and must have cooled down. 1. Follow the steps shown in the M figures. 2. Depress the handles on the grease filters and fold down the grease filters. 3. Clean the grease filters. 4. Re-install the cleaned grease filters. 5. Clearing the display. .. Press 2x in succession the O push button. An acoustic signal is issued and the display goes out. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. * Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine. .. Clean the extractor hood with a hot soap solution or a mild window cleaner. .. Do not scrape off dried-on dirt but wipe off with a damp cloth. .. When clearing the grease filters, remove grease deposits from accessibile parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. .. Note: do not use alcohol (spirit) on plastic surfances, as dull marks may appear. Caution! Ensure that kitch...
Other models in this manual:Range Hoods - LF959RA50/02 (594.17 kb)
Range Hoods - LF959RA50/03 (594.17 kb)
Range Hoods - LF959RA50B/03 (594.17 kb)