|
manual abstract
Saturation – activated carbon filter (a) Switching on manual mode: Switching over to automatic mode: Press the Lor + button. . To switch from manual mode to automatic mode at any time, press the U . The fan starts at Setting }. button. Switching on the fan settings/intensive setting: 1. To increase the fan settings or switch on the intensive setting c, press the + button. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to Setting }after 10 minutes. 2. To switch off the intensive setting c or switch back to fan settings ~ – } – |and switch off the extractor hood completely, press the – button. Operating procedure Switching on automatic mode: Press the Ubutton. . The fan runs at least at Setting |. Fan settings: . If required, the optimum fan setting is actuated automatically via a sensor. . The automatic function operates at Settings | – ~. Intensive setting: 1. To switch on the intensive setting c, press the + button. . Automatic mode has been switched off. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to the optimum fan setting after 10 minutes. 2. To switch off the intensive setting, press the – button. . Automatic mode has been switched on again. Switching over to manual mode: . To switch from automatic mode to manual mode at any time, press the U button. Intermittent ventilation . Used for ventilating the kitchen at hourly intervals at the lowest fan setting, round the clock. Switching on: . Before intermittent ventilation can be switched on, the appliance must be switched off. Press the button. . The fan runs for 5 minutes at Setting |, then switches off for 55 minutes. This process is repeated every hour. Switching off: Press the button. Operating procedure Switching off With fan run-on started from manual mode: Press the button. . The fan runs at the setting last selected. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. With fan run-on started from automatic mode: Press the button. . Fan run-on does not start until the automatic function has switched the fan back to Setting |. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. Without fan run-on: Press the Lbutton. Light . The light can be used at any time, even when the appliance has been switched off. Switching on/off: Press the a button. Special functions Adjusting the sensitivity of the sensor control: 1. Press and hold down the automatic button. 2. To display the current sensitivity, press the + or – button. 3. You can now change the sensitivity of the sensor control by pressing the + or – button. . Factory setting: @. . Lowest setting: {. . Highest setting: O. Switching on the light automatically, e.g. via a timer: . Fan and light must be switched off. Switching on: Simultaneously press the a and L buttons. . After approx. 3 seconds the light switches on to acknowledge the setting. Switching off: Repeat the process with the light switched on. . After approx. 3 seconds the light switches off to acknowledge the setting. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: ~ When the grease filters reach saturation point, an acoustic signal is sounded for 6 seconds after the fan has switched off, and an ~ appears in the display. The grease filters should be cleaned straight away. Cleaning the metal grease filters: . In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. . The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. 1. Press the catch on the grease filters inwards and fold the filters down. At the same time take hold of the underside of t...
Other models in this manual:Range Hoods - LC66955/02 (3.44 mb)