manual abstract


Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the power cord are colour coded as follows: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. Proceed as follows: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. Electrical connection 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood may be connected to a correctly installed earthed socket only. Attach the earthed socket near the extractor hood in an accessible position. . The earthed socket should be connected via its own power circuit. If appliances do not feature the OFF delay function, the indicator may start flashing when the extractor hood has been switched off for several hours via a separate switch, even though the grease filters are not yet saturated. (See instructions for use, section on filter and maintenance). Electrical specifications: These can be found on the rating plate inside the appliance following removal of the filter frames. Before carrying out repairs, always isolate the appliance. Length of the connection cable: 1.30 m. If permanent connection is required: The extractor hood may only be connected by an electrician registered with the local electricity board. A disconnecting device must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnecting devices. These include LS switches and contactors. This extractor hood complies with EU regulations on interference suppression. Fitting the extractor hood To the wall 60 cm wide extractor hood: With 3 screws. 10021 102 57 598 127 536 180 90 cm wide extractor hood: With 5 screws. 898 536 21 102 180 127 100 57 836 1. Mark mounting boreholes. Dimensions can be found in or use template. 2. Drill 8 mm dia. holes and insert wall plugs flush with the wall. 3. Screw in the upper screws (on left and right) until there is a gap of approx. 7 mm between the screw head and the wall. 4. Remove the filter grille (see Instructions for use) 5. Attach the extractor hood. 6. Tighten the lower screw (with washer) inside the extractor hood. 24 Fitting the extractor hood Final assembly 90 cm wide extractor hood: With 6 screws. 163 30 598 1. Dimensions for the mounting boreholes can be found in, or place a template on the base of the wallhanging cupboard. 2. Mark the mounting holes and make pilot holes with a bradawl. In exhaust-air mode (upwards) mark the exhaust-air opening and saw out. . Consider the location of the connection cable; if required, saw out the cupboard. 3. Remove the filter grille (see Instructions for use). 4. Screw the extractor hood to the base of the cupboard. . Connect to the power supply. . Insert the filter grille (see Instructions for use). Exhaust-air mode: . Stick the enclosed covering foil over the air outlet grille on the top of the extractor hood. Ensure that the surface is clean. . Connect the pipes. 2-motor extractor hood Selecting the operating mode: . Exhaust-air mode: Position 1 . Circulating-air mode: Position 2 . Select the operating mode on the left or right with a screwdriver. To a wall-hanging cupboard 60 cm wide extractor hood: With 4 screws. 163 30 30 560 898 30 87,5 Weight in kg: Width Exhaust air Circulating air 60 cm 2 motors 90 cm 10,0 11,0 13,0 14,0 Design changes with respect to technical development shall remain withheld. 1 2 Mode d’emploi: Description de l'appareil Eclairage Commutateurs Eclairage/Ventilateur Grille du filtre Modes de fonctionnement Air evacue a l'exterieur: . Le ventilateur de la hotte aspire les buees de cuisson qui traversent un filtre a graisse avant de regagner l'atmosphere exterieure. . Ce filtre retient les particules grasses solides en suspension dans les buees de cuisson. . Les particules grasses ne se deposent plus dans la cuisine, les odeurs de cuisson disparaissent. DSi la hotte evacue l'air a l'exterieur et si le logement comporte des moyens de chauffage (tels par ex. des appareils de chauffage au gaz, au fuel ou au charbon, chauffe-eau instantanes ou a accumulation) raccordes a une cheminee, veillez imperativement a ce que l'apport d'air soit suffisant pour assurer la marche du chauffage a combustion. Un fonctionnement sans risque est possible si la depression dans le local ou le foyer de chauffage est implante ne depasse pas 4 Pascals (0,04 mbars). On y parvient en presence d'ouvertures non obturables menagees par ex. dans les portes, fenetres et en association avec des ventouses telescopiques d'admission/ evacuation de l'air a travers la maconnerie ou par d'autres mesures techniques telles qu'un verrouillage reciproque ou assimile...

Other models in this manual:
Range Hoods - DHU965U/02 (2.36 mb)
Range Hoods - 3BH726B/01 (2.36 mb)
Range Hoods - 3BH726B/02 (2.36 mb)
Range Hoods - 3BH726B/03 (2.36 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category