User manual Bosch, model DHL555BAU/01

Manafacture: Bosch
File size: 1.57 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Note: When assessing the overall requirement, the combined ventilation system for the entirehousehold must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. All legal requirements concerning the discharge of exhaust air must be observed. Unrestricted operation is possible if the extractor hood is used in recirculating mode –with activated carbon filter. The extractor hood should be fitted with a one-way flap for exhaust-air mode if thereis not already one installed in the exhaust-air pipe or wall box. If aone-way flap is not enclosed with the appliance, purchase one from aspecialist outlet (see optional accessories on the last page). Attaching the one-way flap . Insert the two lugs on the one-way flap into the holes on the air-pipe connector or air outlet and lock into position. ..Beforeinstalling the one-way flap, ensure that the lettering or stamp is on the outside. Optimum performance of the extractor hood: . Short, smooth extraction pipe. . As few pipe bends as possible. . Largest possible pipe diameter (preferably 150 mm o) and large pipe bends. . Round pipes: We recommend for single-motor model, inner diameter of at least 120 mm for double-motor model. inner diameter of at least 150 mm . Flat ducts must have an inner cross- section equivalent to round pipes which have an inner diameter of 120/150 mm. 120 mm l approx. 113 cm2 150 mm l approx. 177 cm2 . If pipe diameters differ: use sealing strip. . Ensureanadequate air supply for exhaust-air mode. Pipe connection Extractor hoods with 120 mm Oair outlet: 100 mm Oextraction pipe . Insert the reducing connector (see optional accessoriesonthe last page) into the air-pipe connector and then attach the exhaust-air pipe. 120 mm Oextraction pipe . Attach the exhaust-air pipe directly to the air-pipe connector. 8 The extractor hood is particularly suitable for installation in a flue or chimney. To ensure optimum extraction performance (especially important for kitchen island solutions): . Install the extractor hood as high as possible within the structure . The structure must cover the entire cooking area. The following cutouts must be made for the installation depending on the model: Extractor hood with rocker switch, 53 cm wide, 1-motor: min 10 min 15 500 -3 260 -3 16 160 47 75 120 248 248 75 100 280 530 12 256 Electrical connection Installation Extractor hoods with 150 mm O air outlet: 150 mm l extraction pipe . Screw the reducing connector (see optional accessories on the last page) onto the air outlet. . Attach the extraction pipe to the reducing connector. 150 mm l extraction pipe . Attach the exhaust-air pipe directly to the air outlet.. .. If a one-way flap has been fitted, conduct a performance test. Extractor hoods with rectangular air outlet: . Screw the enclosed air-pipe connector over the air outlet. Recirculated air mode . The air cleaned by an additional activated carbon filter is conveyed back into the room. . In recirculated air mode the exhaust opening must be protected by a grille (see optional accessories on the last page) in order to prevent a mechanical or electrical hazard. The extractor hood must be connected to a correctly installed earthed socket only. Attach the earthed socket as close to the appliance as possible and in an accessible position. If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be provided on the installation side. Disconnectors are switches with a contact opening of more than 3 mm and all-pole disconnection. LS switches and contactors are regarded as disconnectors. The appliance must be isolated before repairs are carried out. Repairs may be carried out by authorised technicians only. .. If the connection cable of this appliance is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person in order to prevent a hazardous situation. Improper repairs may put the user at considerable risk. Length of connection cable: 1.20 m. Electrical specifications: The electrical specifications can be found on the rating plate inside the appliance when the filter frame has been removed. .. Do not place hand in the air outlet. This appliance complies with the EC radio interference suppression regulations. Prior to installation 9 Extractor hood with slide control, 53 cm wide, 1 and 2-motor: min 15 min 15 500 -3 16 352 -3 9 380 346 530 160 55 95 150 120 248 248 100 35 225 Extractor hood with slide control, 73 cm wide, 1 and 2-motor min 15 min 15 16 352 -3 700 -3 9 346 160 55 95 150 120 348 348 100 35 225 380 730 1. Remove the filter grille (see operating instructions). 2. Connect the power. 3. Press the extractor hood up into the installation opening until the installation aid locks into position at the front and rear. 4. Screw in the extractor hood. 5. Insert and secure the filter grille (see operating instructions). Installation 310 160 150 120 95 60 80 496 9 230 250 380...

Other models in this manual:
Range Hoods - DHL555BAU/02 (1.57 mb)
Range Hoods - DHL555BAU/03 (1.57 mb)
Range Hoods - DHL755BAU/01 (1.57 mb)
Range Hoods - DHL555BGB/01 (1.57 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category