manual abstract


Replace the bulbs with new ones of the same type. Caution: do not touch the light bulb with bare hands. •Commands: (fig.8) mechanical the key symbols are explained below: A = LIGHT B = OFF C = SPEED I D = SPEED II E = SPEED III • Commands: (fi g.9) luminous the key symbols are explained below: A = LIGHT B = OFF C = SPEED I D = SPEED II E = SPEED III F = AUTOMATIC STOP TIMER - 15 minutes (*) • If your appliance does not have the INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. When the function is active the LED fl ashes. To interrupt it before the 10 minutes have expired press key E again. • By pressing key F for two seconds (with the hood switched off) the “clean air” function is activated. This function switches the appliance on for ten minutes every hour at the fi rst speed. As soon as this function is activated the motor starts up at the first speed for ten minutes, During this time key F and key C must fl ash at the same time. After ten minutes the motor switches off and the LED of key F remains switched on with a fixed light until the motor starts up again at the fi rst speed after fifty minutes and keys F and C start to flash again for ten minutes and so on. By pressing any key for the exclusion of the hood light the hood will return immediately to its normal functioning (e.g. if key D is pressed the “clean air” function is deactivated and the motor moves to the 2nd speed straight away. By pressing key B the function is deactivated). (*) The “automatic stop timer” delays stopping of the hood, which will continue functioning for 15 minutes at the operating speed set at the time this function is activated. • Active carbon/grease fi lter saturation: -When button A flashes at a frequency of 2 seconds, the grease filters must be cleaned. -When button A fl ashes at a frequency of 0.5 seconds, the carbon filters must be replaced. After the clean filter has been replaced, the electronic memory must be reset by pressing button A for approximately 5 seconds, until the light on the button stops fl ashing. • Commands: (fi g.10). Push-button A = on/off lights switch Push-button B = on/off cooker hood switch. The appliance switches on at speed level 1, If the cooker hood is on depress the push-button for 2 sec. to switch off the cooker hood. If the cooker hood is at speed level 1 it will not be necessary to depress the push-button to switch the cooker hood off . Decreases the motor speed. Display C = indicates the motor speed level selected and activates the timer. - 5 - Push-button D = switches on the cooker hood. Increases the motor speed. Touching the key at 3rd speed, the intensive function runs for 10’, then the appliance go back to work at the original speed. During this function the display blinks. Key E = The Timer times the functions on activation for 15 minutes, after which they are switched off. The Timer is deactivated by re-pressing Key E. When the Timer is activated the decimal point must flash on the display. The Timer cannot be activated if the intensive speed is functioning. The “clean air” function is activated by pressing key E for 2 seconds when the appliance is switched off. This switches the motor on for 10 minutes every hour at the first speed. During functioning a rotary movement of the peripheral segments must be visualised on the display. When this time has passed the motor switches off and the fi xed letter “C” must be visualised on the display until the motor re-starts after 50 minutes for another 10 minutes and so on. Press any key apart from the light keys to return to normal functioning. Press key E to deactivate the function. • Active carbon/grease fi lter saturation: -When display item C flashes, at a speed where it alternates with the letter F (e.g. 1 and F), the grease filters must be washed. -When display item C flashes, at a speed where it alternates with the letter A (e.g. 1 and A), the carbon filters must be replaced. After the clean filter has been positioned correctly, the electronic memory must be reset by pressing button A for approximately 5 seconds, until the indication F or A shown on the display C stops fl ashing. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE WARNINGS. CESKY CZ UVOD’ Prectete si pozorne obsah navodu, protoze poskytuje dulezite informace tykajici se bezpecne instalace, pouzivani i udrzby zarizeni. Uchovejte si navod pro jakoukoliv budouci potrebu. Pristroj je urcen k odsavani (odvadeni vzduchu ven – obr.1B), filtrovani (recyklace vzduchu v mistnosti – obr.1A). BEZPECNOSTNI OPATRENI 1. Vyzaduje se opatrnost, jestlize jsou soucasne v cinnosti odsavac par a jiny horak nebo tepelne zarizeni zavisejici na vzduchu mistnosti a napajene jinou energii nez elektrickou, protoze odsavac par spotrebovava vzduch z okoli, ktery horak nebo jine tepelne zarizeni potrebuji ke spalovani. Negativni tlak nesmi prekrocit 4Pa ...

Other models in this manual:
Range Hoods - CWB 9550 X (3.04 mb)
Range Hoods - CWB 6550 X (3.04 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category