|
manual abstract
1.14- Children should be supervised to ensure that they do not play with the appliance. EN 4 INSTALLATION 2 - INSTALLATION INSTRUCTIONS Some installation systems require the opening and removal of the metal grille panel. 2.1 -Instructions for opening and removing the metal grille panel To open the grille panel, press inwardly on the two slider catches at each side of the grille panel and the grille will pivot down. To remove the metal grille, pull forward on the right hand side so that the hinge pin on the back of the grille will be released from the slot in the side of the casing. 2.2 -Wall cabinet fixing a - Predrilled wall cabinet: fix the hood onto the wall cabinet base panel using the four screws 4.2 x 45 mm (supplied with the fixing kit). It is not necessary to open the metal grille. b - No predrilled wall cabinet: b.1 -If the hood is provided with a paper fixing template, follow the instructions. b.2 -If the hood is not provided with a paper fixing template, position the hood on the wall cabinet base panel and pilot drill the 3.5 x 16 mm screws (not supplied with the fixing kit) from the inside onto the wood. 2.3 -Wall mounting a -Drill two O 8 mm holes on the wall using the paper template, insert two rawl plugs and two 4.2 x 44,4 mm screws leaving 5 mm untightened. Open the metal grille panel, hook the hood on and fully tighten the screws. b - If the hood is not provided with a paper fixing template, drill two O 8 mm holes (see draw.), insert the plugs and screws, proceeding as directed under paragraph a. c - For wall mounting using wallbrackets (optional), follow the instructions of the fixing template. d - Pay attention to the safety regulation of point 1.6. 2.4 -Choice of operating mode a - Evacuation mode To check that the hood is set up for evacuation, open the grille panel and make sure that the conversion lever or the change-over knob on the centrifugal unit is in the DUCTING position. The charcoal filter is not required. For ducting to the outside, the hood is supplied with a rear and top outlet. A flange spigot of 100 mm diameter (120 mm in certain models) is usually fitted on the top outlet and a blanking plug on the rear outlet. If you choose to duct the hood from the rear of the casing, you should invert the position of the flange and of the blanking plug. Pay attention to the safety regulation 1.1. b - Internal recirculation mode To check that the hood is set up for recycling, open the grille panel and make sure that the conversion lever or the change-over knob on the centrifugal unit is in the RECYCLING position. The charcoal filter is to be fitted. To fit the charcoal filter, support the filter with one hand and turn the thumb screw through the centre of the charcoal filter. If the filter is of the interlocking type, turn the filter clockwise. The hood can remain connected to the outside. 2.5 -Electrical connection and working test 1 - The safety measures 1.2, 1.3, 1.4 and 1.5 of paragraph 1 are to be strictly observed. 2 - Once the electrical connection has been completed, check that the worktop illumination, motor and speeds work properly. EN 5 USE - MAINTENANCE 3 - OPERATION 3.1-Controls are located on the right hand side of the front to operate worktop illumination and select the most suitable working speed for your cooking. To increase the area of extraction, the glass visor should be pulled open. The top speed should be used when frying or cooking foods with strong odours, while a lower speed can be used for normal cooking. To obtain the best performance from your hood, turn it on before you start cooking and leave it running for a few minutes after your cooking is over to clear the air. 3.2-Pay attention to safety regulations 1.7 and 1.8. 4 -MAINTENANCE AND CLEANING Regular maintenance and cleaning will ensure good performance and reliability, while extending the working-life of the hood. Special attention should be reserved to the grease filter and to the charcoal filter (recycling mode). 4.1 -Grease filter This retains the solid grease particles and can be supplied in different types. lt is fitted onto the reverse side of the metal grille panel. Maintenance of the grease filter varies according to the used type. a-Whatever type of filters used, the filter is easily removed from the grille by pushing the metal wire clips to one side and removing. b-Thin synthetic filter (1 mm thick). It should not be washed and should be replaced every two months. If the filter is provided with a saturation indicator, replace when: b.1-The violet colour of the dots, which are visible through the metal grille, is spread over the whole surface of the filter. b.2-The red colour of the stripes, which is not visible through the metal grille when the filter is clean, becomes visible from the outside of the metal grille. c-Multi-layer metal filter. It should be washed once a month in hot water using mild detergent or liquid soap. It can be washed in a dish-washer. It should not be bent and should be ...
Other models in this manual:Range Hoods - ZHT 530 (285.33 kb)