downloaded: 1   File size: 193 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

Position the metal screen mesh so it is facing upward when the lid is closed. Lid Assembly The F111 lid is held in place by two separable hinges and two spring loaded plungers. To install the spring loaded plungers on the lid follow these steps: 1. Pull the plunger back and twist a quarter turn to reveal the wrench flat on the body of the spring loaded plunger (see Fig 6.) 2. Turn the threaded barrel out of the spring plunger. 3. Insert the threaded barrel through the hole in the lid and turn th

downloaded: 1   File size: 149 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

Because the F114 provides its own air circulation, it can be used in any application that requires contamination reduction in an enclosed area. SPECIFICATIONS Models: F114A Ceiling Surface-Mounted Media Air Cleaner with 99.97% HEPA filters; without CPZ canisters. F114C Ceiling Surface-Mounted Media Air Cleaner with 95% DOP filters; with CPZ disposable canisters. Color: White grille with white plenum. Electrical Ratings: 120V, 60 Hz, 1PHS, 3.6A; 220/240V, 50/60 Hz, 1PHS, 1.7A. Electrical

downloaded: 5   File size: 374 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

The air going to the unit and the discharged air may be transported by a network of ducting and plenums or the unit can be used independently. The Honeywell Trademark is used under license from Honeywell Intellectual Properties, Inc. by Air-Pure Systems. Honeywell International Inc. makes no representations or warranties with respect to this product PRODUCT DATA FEATURES • Variety of filter configurations available to customize the air cleaner for any application. • Three-speed direct drive forw

downloaded: 0   File size: 490 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

This is particularly important in homes with heavier contamination from smoking or fireplaces. 10500 Series... The Honeywell 10500 Series air cleaner is a 2 speed air cleaner. As a safety feature, when the filter cage cover is removed, the switch will automatically be placed in the off position. The unit cannot be turned on with the filter cage cover removed. To operate the unit, turn the round switch to the high setting and then adjust to the desired speed. International symbols indicate off ,

downloaded: 1   File size: 618 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

9. Horizontal furnace, with media air cleaner mounted vertically in return duct near furnace. M946A Fig. 10.Two or more media air cleaners used in a high capacity system. Determining Sheet Metal Requirements The media air cleaner is adaptable to all new or existing forced air heating and cooling systems used in residential applications. Transitions or turning vanes may be required in some applications for effective media air cleaner operation. Transitions Transitions are needed when the duct is

downloaded: 6   File size: 490 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

0 1 2 3HEPA CPZ 0 1 Hru0 1 2 3HEPA .................... 0 1 2 3 250i 0 1 2 3HEPATrue 0 1 2HEPATru 0 1 2 150i Owner's Guide For Model Series 10500 • 11500 • 12500 • 13350 • 13500 and 14500 Air Cleaners The Science of Clean Air™ Important Safety Instructions ... PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Save these instructions for easy reference. When using electrical appliances, basic precautions should always be followed to reduce breakage, risk of fire, electric shock and injury t

downloaded: 5   File size: 167 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

1. Air Cleaner components. 69-1506-4 6 Determining What to Do When Your Air Cleaner Does Not Operate • Check to make sure the power cord is correctly connected in the outlet. • Test the outlet with another appliance or lamp. • Check the fuse or circuit breaker; the circuit may be overloaded if other appliances are also in use. • Check to determine if the thermal overload protection device on the air cleaner motor has engaged to turn off the air cleaner. If it has, turn the air cleaner motor cont

downloaded: 1   File size: 643 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name@name@name

Read all instructions before operating the air purifier. 2. Place air purifier where it is not easily knocked over by persons in the household. 3. Always turn the air purifier to the OFF position and unplug from the wall outlet when not in use. 4. To disconnect the air purifier, first turn control to the OFF position, grip the plug and pull it from the wall outlet. Never pull by the cord. 5. Do not use any product with a damaged cord or plug or if product malfunctions, is dropped or damaged in a

downloaded: 2   File size: 404 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name

and/or to third party software vendors. Before software delivery, the end user must execute a software license agreement that governs software use. Software license agreement provisions include limiting use of the software to equipment furnished, limiting copying, preserving confidentiality, and prohibiting transfer to a third party. Disclosure, use, or reproduction beyond that permitted in the license agreement is prohibited. Trademark Information CentraLine and 'close to you' are trademarks of

downloaded: 1   File size: 643 kb   Manafacture: Honeywell  
Category: Air Cleaners
@name@name@name

1). HEPA FI L T E R PREFILT E R I II 0III Fig 1 Removing/Changing the Filters CAUTION: DISCONNECT FROM POWER SUPPLY BEFORE SERVICING Do not attempt to wash either the carbon pre-filter or the HEPA filter. They are not washable and washing will damage the filters. The only two parts requiring any service are the carbon pre-filter and the HEPA filter. No tools are needed. To remove or change either filter, disassemble the unit as shown below: Fig. 3 Step 1: Turn the air purifier off and unplug fro