Login:
Sorted: Name ↓   Downloads   Rate   Size ↑  
downloaded: 3   File size: 70 kb   Manafacture: Carrier  
Category: Air Cleaners
@name

of insulation from wire. Splice wires to new power supply wires with wire nuts provided in kit. (See Fig. 1.) 3. Remove existing surge resistor, if applicable, and discard. Surge resistor is an integral part of the new power supply. 4. Install proper length bus bar. 5. Route wires so they will not contact high-voltage circuit and install wire clip. 6. Reinstall power door in air cleaner. 7. Turn on main electrical supply to the air cleaner and air handler. 8. Check air cleaner for proper operati

downloaded: 0   File size: 798 kb   Manafacture: Carrier  
Category: Air Cleaners
@name

Remove screw holding contact spring to cells and reinstall at opposite end (See Fig. 17). Be sure all airflow arrows are pointing in the direction of the airflow through the air cleaner and that the prefilters are on the entering-air side. 3. Deform prefilter guide on side opposite prefilters so that prefilters may not be reinstalled incorrectly. 4. Replace power door by first inserting bottom tab into place on bottom edge of door opening. Push top of door and guide door attachment knob screw

downloaded: 6   File size: 1 mb   Manafacture: Carrier  
Category: Air Cleaners
@name

5 — Junction Box and Top Guide Fig. 8 — Typical Furnace Wiring with Multispeed Fan Motor and Sail Switch THERMOSTAT CONNECTIONS Fig. 6 — Typical Furnace Wiring with Single-Speed Fan Motor -120 V -O-g-Q- LS ps THERMOSTAT CONNECTIONS Fig. 7 — Typical Furnace Wiring with Multispeed Fan Motor and Air Cleaner Relay Il5V HUMIDISTAT II5V HUMIDIFIER^ HUl L2 I-----3- | DIRECT DRIVE WIRING F- i2 5 LO L- I 4 MED i^T^i W 3 ! I 6 —H ; H №)-----rjf[H ■—-0 24V HUMIDISTAT 24 V HUMIDIFIER L

downloaded: 0   File size: 1 mb   Manafacture: Carrier  
Category: Air Cleaners
@name

When outdoor air is added, make certain that it is far enough ahead of the air cleaner to be mixed and warmed properly. If not, baffles must be installed to force mixing of the air. 2. Preheat coil. If a large amount of outdoor air is used, it must be heated. A thermostat should be used to control the heater. (A strip heater or hot water coil are typical heaters.) INSTALLATION PROCEDURE Remove Filter and Clean Blower Compartment Before Starting Installation. 1. Remove and discard the old fil

downloaded: 0   File size: 1 mb   Manafacture: Carrier  
Category: Air Cleaners
@name

See Power Door. 2. Disconnect surge resistor at power supply. 3. Remove screws holding the bus bar. Cell — Plate-type and media-type, Fig. 14. The cell contains the ionizer wires, the ionizer ground plate, Fig. 15, item 1, and the charged and grounded collector plate assembly, item 3, of the plate-type cell. The plate-type and media-type cleaners are the same electrically. Physically, however, while the media-type cell has the same type of ionizer as the plate-type, a fiber glass pad between

downloaded: 0   File size: 446 kb   Manafacture: Carrier  
Category: Air Cleaners
@name

(mm) 1...381 1...381 1...381 2...381 2...381 2...381 2...457 2...457 Nominal Airflow (L/s) 1416 1605 1888 2360 2831 3775 4719 5663 Airflow Range (L/s) 10621770 12042006 14162360 17702949 21243539 28314719 35395899 42477079 Nominal Motor kW (Standard Motor) 208/230-1-60 1.79 1.79 — — — — — — 208/230-3-60, 460-3-60 1.79 1.79 1.79 1.79 2.76 3.73 5.60 7.46 575-3-60 1.49 1.49 1.49 1.49 2.24 3.73 5.60 7.46 230-3-50, 400-3-50 1.79 1.79 2.16 2.16 2.16 3.73 5.60 7.46 Motor Speed (r/s) 208/230-1-60 28.8 2

downloaded: 1   File size: 446 kb   Manafacture: Carrier  
Category: Air Cleaners
@name

4 for access hole location by number. †Fittings are listed in order from header or tee stub connection out to access hole in corner support post. 16 Table 3 — Fitting Requirements (cont) UNIT ACCESS HOLE NO.* CONNECTION TYPE CIRCUIT FITTINGS REQUIRED† (in.) 40RMS 028, 034 5 Supply Lower 21.8 Long Radius Elbow 21.8 Nipple, 31.2 L 21.8 Long Radius Elbow 6 Return Lower 21.8 Long Radius Elbow 21.8 Nipple, 3 L 21.8 Long Radius Elbow 7 Return Upper 21.8 Long Radius Elbow 21.8 Nipple, 67.8 L 21.8 Long

downloaded: 2   File size: 446 kb   Manafacture: Carrier  
Category: Air Cleaners
@name

2 *Preferred inhibitors. lubricant because it contains rust and oxidation Fig. 17 — Fan Shaft, Bearings, and Fan Wheel (Typical) 23 Centering Fan Wheel — If fan and fan shaft assembly are not properly centered, blades may scrape against scroll or may create an objectionable whistling noise. It may be necessary to adjust individual fan wheels or move entire fan shaft. See the following two sections. Fan Shaft Position Adjustment — Loosen setscrew or locking collar of each fan shaft bearing. Slide

downloaded: 1   File size: 1 mb   Manafacture: Carrier  
Category: Air Cleaners
@name

If an atomizing humidifier must be mounted upstream of the Infinityt Air Purifier, it should be mounted as far upstream as possible (at least 6 ft. recommended), and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets. Transitions If the return air duct or fan coil openings do not fit the Infinityt Air Purifier cabinet openings, gradual transitions are recommended to reduce air turbulence and maxim

downloaded: 0   File size: 2 mb   Manafacture: Carrier  
Category: Air Cleaners
@name

Contact local Carrier distributor for information on approved alternatives. Door (x1) Cabinet (x1) Enhancement Module (x1) Safety Screen (x1) Installation Manual Duct Gasket Tape (1 roll) Furnace Adapters (x2) Return Duct Adapters: Long (x2) / Short (x2) Air Purification Cartridge (x1) (x2) (x2) (x1) (x1) (x2) Installation Components (in bag attached to power cord) A06027 Fig. 2 -- Infinityt Air Purifier Components GAPA 3 INSTALLATION Step 6—Check Infinityt Air Purifier Components CUT HAZARD Fai





Category