|
manual abstract
Room air is drawn into the Air Cleaner through the Air Intake Grille and passes through the filters. The filtered air is released from the top of the unit and is dispersed upwards into the room. Two Filter Change Calendar Wheels are provided on the Air Cleaner control panel to serve as convenient reminders when to change the filters. SET UP Your Air Cleaner was thoroughly inspected and tested at the factory prior to packaging. Visually inspect it upon removal from its box. Remove and discard any packaging material. Return the unit if it shows any signs of damage or mishandling. Upon starting your Air Cleaner, set the Pre-filter Calendar Wheel ahead 3 months and the HEPA Filter Change Calendar Wheel ahead 12 months to remind you when the next filter replacement is needed. ELECTRICAL HOOKUP Plug the Air Cleaner into a polarized 120-Volt AC wall outlet. i Z_WARNiNG: To avoid the risk of fire or electric shock hazard, the i Air Cleaner should ONLY be plugged into a polarized 120=Volt AC outlet. OPERATION Z_ CAUTION! NEVER operate the Air Cleaner without the HEPA filter properly installed. Permanent motor damage could result. Each time you start the Air Cleaner, it is a good idea to run it at Turbo speed for a few seconds. Then set it HI, MED or LO as desired. OPERATION cont. oTURBO = HI • MED • LO initial Operation Maximum Operation Daytime Operation Nighttime Operation Fastest Cleaning Fast Cleaning Normal Cleaning Quieter Operation FILTER CHANGE SCHEDULE Pre-Filter: The pre-filter should be changed every three (3) months or sooner, depending upon the level of the room's air contaminants and the frequency of use. = HEPA Filter: The usable lifetime of the HEPA filter is 1 -3 years, depending upon the level of the room's air contaminants and the frequency of use. The air volume output will begin to decrease dramatically when the filter needs to be changed. You should have a spare filter available for later replacement. FILTER REPLACEMENT These filters are specially designed for easy replacement at maximum performance. THE FILTERS ARE NOT WASHABLE. 1. Turn the air cleaner OFF and unplug it from the power outlet. 2. Carefully lay the unit down on a flat surface with the Front Grille facing up. 3. Gently push in on Release Buttons on both sides of the unit and swing out the Front Grille. 4. Pre-Filter • The pre-filter is attached to the HEPA filter frame with six adhesive pads. Detach pre-filter and discard it. • Remove and discard any plastic protective wrapping from the new pre-filter. • Lay pre-filter on HEPA filter and gently push it against adhesive pads to attach it to the HEPA frame. 5. HEPA Filter , Remove and discard any plastic protective wrapping and packaging from the new HEPA filter. oAttach a new pre-filter to the new HEPA filter frame see Pre-Filter attachment instructions above). Note: Always install new pre=filter when changing HEPA filter. • Place the filter assembly into the unit. 6. install the Front Grille by engaging its tabs into the bottom slots on the unit. Then swing grille up and gently push in top to snap into place. 5 FILTER REPLACEMENT cont. 7. Adjust the filter change wheels to properly indicate when the next filter change is necessary. 8. Turn the Air Cleaner upright and plug it into an outlet for operation. Model 32-85254 Modem32-85250 Pre-Pro- Filter Filter Filter Fimter Release LRelease Buttons Buttons Tabs _ Slots Tab_ Slots NOTE: Model 85254 has a built-in ionizer which additionafly helps dean, freshen and revitalize the air. CLEANING THE UNiT I Z_WARNING: To avoid serious injury from electric shock ALWAYS turn the air cleaner OFF and disconnect the plug from the out|et BEFORE cleaning. 1.Turn Air Cleaner OFF and unplug from outlet. 2. Clean unit with a moistened soft cloth only. DO NOT pour or splash water on the unit or use any abrasive-type cleaner on it. Clean all external surfaces, especiafly the air intake grilles and air outlet. 3. DO NOT attempt to dean the pre-filter or HEPA filter; they ARE NOT washable and washing will damage them. 4. Reposition Air Cleaner plug into power outlet and turn ON. STORAGE if you store your Air Cleaner for more than 30 days you should: 1. Remove both the HEPA filter and the pre-filter from the unit. 2. Discard the pre-filter. 3. Wrap the HEPA filter in an air-tight plastic bag or plastic wrap. Be sure that the filter is totally sealed to protect it from its storage environment. 4. DO NOT put the plastic-wrapped HEPA filter back into the air cleaner. 5. To restore the Air Cleaner to service: Unwrap the HEPA filter. , Instafl a new charcoal pro-filter. , Instafl filter assembly in the air cleaner. See "Filter Replacement" section for proper installation. 6 TECHNICAL SPECiFiCATIONS Length 16.5 in. (41.9cm) 21 =7/8in. (55.6 cm) Width 6.7 in. (17.5cm) 8-1/2in. (21.6 cm) Height 15.4 in. (39cm) 18 in.(45.7cm) Weight 9.4 Ibs.(4.28 kg) 15.1 Ibs. (6.84kg) Input Voltage 120 volts AC, 60 Hz 120 volts AC, 60 Hz REPLACEMENT PARTS Pre-Filter 83156 83157 H...
Other models in this manual:Air Cleaners - HEPA 152.85254 (1.19 mb)