Manafacture: Sharp
File size: 1.84 mb
File name: 3eae8a57-a1e8-476a-ad4e-35423a4732e3.pdf
|
manual abstract
FP-N40CX R Floor / Tabletop type Type mobile *Plasmacluster is a trademark of Sharp Corporation. *Plasmacluster est une marque de commeree de Sharp Corpration. FP-N40CX AIR PURIFIER OPERATION MANUAL PURIFICATEUR D’AIR MANUEL D’UTILISATION ENGLISHFRANCAIS ENGLISH ENGLISH S Plasmacluster Ion Control The unit controls the ratio of negative ions and positive ions depending on the condition of the room. • Clean Mode Approximately the same numbers of positive and negative ions are discharged. • Ion Control Mode Plenty of negative ions exist in natural surroundings such as waterfalls or forests. In this mode, negative ions will be released in an increased rate, in order to bring the room air close to this natural environment. • AUTO Plasmacluster Ion Mode The unit will switch between Clean Mode and Ion Control Mode automatically depending on the amount of impurities in the air detected by the dust and odor sensor. • Filters 1) Pre-Filter It collects large particles. 2) Washable Active Carbon Filter Its deodorizing performance can be maintained by washing. 3) True HEPA (High Efficiency Particulate Air) Filter with antibacterial Apatite Filter High-efficiency particle collection including pollen and dust. FILTER MAINTENANCE Some odor ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odor. Depending on the usage environment, the air outlet odor may become strong after several months. In this case, clean the Washable Active Carbon Filter. (Refer to E-14) If this odor persists, this is because the odor components absorbed by the HEPA Filter have come off the filter. Purchase the optional filter FZN40HFU and replace the original filters. CONTENTS • FOR YOUR PROTECTION (U.S.) ...............E-2 • CONSUMER LIMITED WARRANTY (U.S.) .E-3 • FOR YOUR PROTECTION (CANADA) .......E-4 • LIMITED WARRANTY (CANADA) ...............E-5 SAFETY PRECAUTIONS ........................ E-6 • RISK OF ELECTRIC SHOCK ......................E-6 • CAUTIONS CONCERNING THE OPERATION OF THIS PRODUCT ..............E-7 • REMOTE CONTROL LIMITATIONS ............E-7 • INSTALLATION GUIDELINE........................E-7 • FILTER GUIDELINES ..................................E-7 PART NAMES.......................................... E-8 • MAIN UNIT DISPLAY...................................E-8 • BACK ...........................................................E-9 • ACCESSORIES ...........................................E-9 • MOUNTING THE STAND ............................E-9 PREPARATION...................................... E-10 • FILTER INSTALLATION ............................ E-10 • INSERTING BATTERIES IN THE REMOTE CONTROL ................... E-10 • REMOTE CONTROL USE......................... E-11 OPERATION .......................................... E-12 • MAIN UNIT OPERATION .......................... E-12 • REMOTE CONTROL OPERATION .......... E-13 CARE AND MAINTENANCE ................. E-14 •WASHABLE ACTIVE CARBON FILTER CARE ........................................... E-14 • FILTER CLEANING................................... E-15 • MAIN UNIT ................................................ E-16 • ODOR SENSOR ....................................... E-16 • FILTER REPLACEMENT GUIDELINES ............................................ E-17 OPERATION GUIDE .............................. E-18 TROUBLE SHOOTING.......................... E-19 SPECIFICATIONS ................................. E-20 Thank you for purchasing the SHARP FP-N40CX. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: “Safety Precautions.” After reading this manual, retain it in a convenient location for future reference. This product is for household use only. ENGLISH E-1 FOR YOUR PROTECTION (the United States) FOR YOUR PROTECTION (the United States) MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE: Dial 1-800-BE-SHARP (237-4277) for: SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem. E-2 CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY Your Product Model Number & Description: Warranty Period for this Product: Additional Item(s) Excluded From Warranty Coverage (If any): Where to Obtain Service: What to Do to Obtain Service: FP-N40CX Air Purifier. Be sure to have this information available when you need service for your Product. One (1) year parts and labor from date of pur...