manual abstract


The air cleaner removes airborne particles such as dust, soot, mold spores, pollen and some cooking smoke from the air circulated through the filter. FEATURES • High Efficiency Particulate Air (HEPA) filter models are 99.97% efficient and the hospital grade particle filtermodels are 95% efficient at 0.3 micron particles. Both models are more efficient on particles smaller andlarger. There is also a 95% ASHRAE model. • Circulates up to 1230 cfm. • Designed to overcome the increase in air flow resistance normally caused by filter loading. • White or black color cover to complement the ceiling. • CPZ™ module removes up to 95% of the space odorsfor up to 24 months. • READ AND SAVE THESE INSTRUCTIONS Contents Application.........................................................................1 Features ............................................................................1 Specifications ....................................................................2 Ordering Information .........................................................2 Planning the Installation ....................................................3 Installation .........................................................................4 Operation...........................................................................6 Service ..............................................................................6 Parts List ...........................................................................8 Limited Two-Year Warranty ...............................................10 The Honeywell Trademark is used under license from Honeywell Intellectual Properties, inc. by Air-Pure Systems. Honeywell International Inc. makes no representations or warranties with respect to this product 68-0198EF-4 F111 (SERIES 1,2) IN CEILING MEDIA AIR CLEANER SPECIFICATIONS IMPORTANT Models: Refer to Table 1 for model descriptions. The specifications given in this publication do not include normal manufacturing tolerances. Therefore, Color: White or black cabinet and cover. this unit may not exactly match the listed specifications. Also, this product is tested and calibrated Blower/Motor: Single speed direct drive forward curve. under closely controlled conditions, and some minor differences in performance can be expected if those Dimensions: See Fig. 1 for dimensions. conditions are changed. Table 1. F111 (Series 1,2) Description. Model Voltage Efficiency Gas, V.O.C. and Odor Control Modules (2) Air Volume in cfm (m3/hr) Particulates at 0.3 Micron (DOP Test) V.O.C./Odor (Most Gases/ Odors First Pass Average) F111A1063 (11006) 120 Vac, 60 Hz, 1PHS, 6.5A 99.97% HEPA N/A N/A 1000 (1700) F111A1253(11025) 120 Vac, 60 Hz, 1PHS, 6.5A 95% ASHRAEa CPZ™ availablea b 1230/1125c F111A2007 208/230 Vac, 50/60 Hz, 3.7A 99.97% HEPA N/A N/A 1000 (1700) F111C1012 (11001) 120 Vac, 60 Hz, 6.5A 95% 85% CPZ™ modules 1000 (1700) F111C1038 (11003) 277 Vac, 60 Hz, 2.8A 95% 85% CPZ™ modules 1000 (1700) F111C1053 (11005) 208/230 Vac, 50/60 Hz, 3.7A 95% 85% CPZ™ modules 1000 (1700) N/A = not applicable. aPurchase filters separately. bDepends on filters used. c1230 or 1125 when used with CPZ modules. TOP VIEW Installation Weight: Approximately 115 lb to 155 lb (kg) depending on the filter con 3/8 X 16 INTERNAL figuration. Refer to Table 2. THREAD (4) Table 2. Sorbent Module Weight. 24 (610) 46-3/4 (1187) 22-1/2 (572) POWER CONNECTION POINT Media Weight in lb (kg) CPZ™ module 43 (20) Sound Level at 3.3 ft (1m): Low speed: 53 dBA (when using optional variable speed switch). 17-1/4 (438) High speed: 61 dBA. CEILING 4-1/2 LINE Grille Type: Perforated metal. (114) M11996A Mounting: Recesses into opening on the ceiling. Fig. 1. Approximate Dimensions of F111 in in. (mm) Ordering Information If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Commercial Air Products Distributor. 2. Air-Pure Systems. 16873 Fish Point Rd. SE Prior Lake, MN 55372 Phone: (800) 998-1919 Fax: (800) 221-3248 48 (1219) 68-0198EF-4 2 F111 (SERIES 1,2) IN CEILING MEDIA AIR CLEANER Approvals: Underwriters Laboratories Inc.: Listed. Canadian Standards Association: Listed. Accessory: 32000234 Variable Speed Switch. Replacement Parts See Parts List, Table 4. PLANNING THE INSTALLATION The number of F111 (series 1,2) air cleaners that are needed is determined by taking into account the number of occupants and the volume of the space. Type of contamination, outdoor air quality and use of the area are also factors. Refer to Table 3 for general guidelines when determining how many air cleaners are needed. EXAMPLE: One air cleaner can provide 2.5 air changes per hour in a 24,000 cubic feet (720 cubic meters) no smoking area. Table 3 suggests two air cleaners for a 24,000 cubic feet area because most areas have contaminants that require more units to provide quality air. If any questions should arise concerning ...

Other models in this manual:
Air Cleaners - F111 Series 2 (192.89 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category