Login:
Votes - 2, Average rating: 4 ( )

User manual Bryant, model AIRT PURIFIER

Manafacture: Bryant
File size: 1.76 mb
File name: d957fc4c-28c3-48ca-8d9f-1dc20f166a46.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


2 -- Perfect Airt Purifier Components GAPA 3 INSTALLATION Step 6—Check Perfect Airt Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. ! CAUTION b. Carefully remove all items from the box. Step 7—Identify Mounting Location a. Identify a mounting orientation for the Perfect Airt Purifier in the return air duct (see Fig. 3). b. Ensure airflow direction through the Perfect Airt Purifier matches the arrows on the face of the air purifier cartridge. The Perfect Airt Purifier can be rotated 180 degrees to accommodate the cabinet orientation. c. The location of the Perfect Airt Purifier should be readily accessible. Enough room should be provided for periodic replacement of the air purifier cartridges. ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death. Only a trained, experienced service person should install the Perfect Airt Purifier. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. Tag disconnect switch with lockout tag. ! WARNING Airflow Airflow Upflow Furnace with Side Return Horizontal Application Upflow Furnace with Bottom Mount Downflow Furnace with Top Mount Airflow NOTE: Mounting on this side requires the cabinet to be rotated 180° for correct air flow. Airflow A06067 Fig. 3 -- Perfect Airt Purifier Cabinet Orientation GAPA 4 Step 8—Mount the Cabinet ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage. Cabinets will support a maximum weight of 400 lbs when installed beneath a vertical furnace or air--handling unit. When setting furnace on cabinet, do not drop it into place. Position the furnace correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components. ! CAUTION a. Turn off power to the heating and cooling system. b. Remove the existing furnace filter and discard. Excessive system static may result if the Perfect Airt Purifier is used with other filtration devices. c. Remove the air purifier cartridge and enhancement module from the Perfect Airt Purifier cabinet. d. Position the cabinet between the furnace and return air duct (see Fig. 4). A transition duct may be required. e. Furnace adapters have been included for installer convenience. They are designed for top or bottom mount installations (see Fig. 5). f. Return air duct adapters have been included for installer convenience. They should be used to connect the upstream side of the air purifier cabinet to the return air duct (see Fig. 6). g. Install foam tape between the furnace and the air purifier cabinet. h. Mounting holes are provided for ductwork and furnace attachment. UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. Mounting holes are provided for duct work and furnace attachment. The screws on the down--stream side of the cabinet should be installed so that the screw heads are inside air purifier cabinet to prevent damage to the air purifier cartridge. ! CAUTION i. Seal seams with tape or caulking after the Perfect Airt Purifier cabinet has been secured. Furnace Adapters (x2) Return Duct Adapters (x4) Return Duct Top Mount Bottom Mount Furnace Adapters (x2) Return Duct Adapters (x4) Return Duct Side Mount A06029 Fig. 4 -- Mounting Perfect Airt Purifier Cabinet GAPA Furnace Adapters a. Ensure power has been removed from the heating and cooling system. b. Turn the Perfect AirtPurifier power switch off. c. Connect the power cord to the power supply connector (see Fig. 7). d. Route the power cord through nearest cabinet hole and protect with enclosed cable connector. Zip ties have been enclosed to secure the power cord to the side of the Airflow power supply. e. Attach the quick connect terminals to the furnace EAC- --1 and EAC- --2 spade connections. Attach the ground ring to furnace chassis ground. Airflow A05274 Fig. 5 - --Use of Furnace Adapters NOTE: The Perfect Airt Purifier is to be powered by 115v/60 Note (optional): Slip return duct adapters onto flanges on air return duct side A05277 Fig. 6 - --Use of Return Duct Adapters Step 9—Wiring ! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. CAUTION! EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. This unit cannot be powered directly from blower motor leads. Voltages...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category