Login:
Votes - 4, Average rating: 4.3 ( )

User manual Guardian Technologies, model GERM GUARDIAN EV9102

Manafacture: Guardian Technologies
File size: 437.45 kb
File name: ev9102_0909_manual.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


Date Purchased month ________ year _________ REV0909 ONLINE WARRANTY REGISTRATION E-1 ©2009 Guardian Technologies LLC PLEASE READ AND SAVE ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE How It Works The Germ Guardian's powerful fan moves air through the center chamber where germs are bombarded with ultraviolet-C light. The highly reflective chamber maximizes the germ-killing power of the UV-C light and the microorganisms passing through it are destroyed. Sanitized air then flows back into the room. DANGER: Electrical Shock Use this product only as described in this manual.• Operate this product on 120V AC, 60HZ only.• IMPORTANT SAFETY INSTRUCTIONS - This portable luminaire has a polarized plug (one blade • is wider thatn the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless plug can be fully inserted. Do not alter the plug. Do not operate this product with a damaged cord or if there is any physical damage to the unit.• WARNING: the cords, wires and/or cables supplied with this product contain chemicals, including lead or lead compounds, known to the state of california to cause cancer and birth defects or other reproductive harm; Wash hands after using. This product is for indoor use only.• Do not operate this product in any area where there is a risk of the unit falling into or being • exposed to water. WARNING: Electrical Shock TO reduce the risk of injury Always unplug the unit before servicing.• Children cannot recognize the hazards associated with the usage of electrical • appliances. For this reason, always supervise children when they are near the device. Do not carry this unit by the cord or use the cord as a handle.• Do not handle the unit or plug with wet hands.• Keep the cord away from heated surfaces.• Do not unplug the unit by pulling on the cord. Grasp the plug itself, when unplugging from • an outlet. Do not put any objects into the openings or block the airflow to the unit.• Do not operate without cover in place.• Do not defeat interlock switch.• Do not operate with an extension cord.• Opening windows or doors while operating this device may affect performance.• This device should not be used in the presence of oxygen or any flammable liquid or gases.• CAUTION ULtraviolet-c light is emitted from the bulb when the unit is electrified. sever eye injury or skin irritation could result. do not operate the unit if the enclosure is damaged. do not expose skin or eyes to within 3-inches of the air intake or output for a period of 3 hours or more. skin or eye irritation could result. NOTE: It is recommended to run the EV9102 continuously. Opening doors and/or windows may affect the performance of the device. E-2 E-3 UV-C Light Bulb & Filter Directions for Use Ultraviolet light technology, the same technology used in hospitals and commercial settings for sanitizing, is capable of eradicating mircoorganisms, mold spores and viral contaminants from the air. It is recommended that you leave the Germ Guardian UV-C Air Sanitizer running continuously. A replaceable 9-watt UV-C light bulb is guaranteed to last 8,000 hours - almost a full year of continuous use. A filter that helps reduce odors is also in the product and should be replaced once a year. Over time, with use, the 9-watt UV-C bulb will lose some intensity (about 15% at 9,000 hours), therefore it is suggested that the light bulb be replaced once every year. You will know when to change the 9-watt light bulb when it continuously flickers or changes color. The replacement bulb and filter come in one package. To reorder bulb & filter pack EV9LB or EV9LBL, please call Customer Service 1.866.603.5900 or go to Plug unit into a 120V AC electrical outlet.1. Switch the power button to the ON position. 2. A small red light should light up on the switch. Use the knob next to the power switch to 3. adjust the fan speed. Turn the knob clockwise for increased air flow. For best results continuous operation 4. is recommended. Note: the germ guardian unit contains no serviceable parts except its uv-c bulb and filter. the bulb and filter may be removed for replacement. WARNING: Electrical Shock Important Safety Instructions under no circumstances should you clean the bulb, bulb holder or cylinder with water or wet solutions. This could cause electrical shock. WARNING: Electrical Shock Always unplug the germ guardian unit from electrical outlet when servicing. Use of the Germ Guardian Unit When the Germ Guardian is turned on you will see two rings of blue light that let you know it is working. The Germ Guardian UV-C Room Air Sanitizer can process 1,380 cubic feet of air per hour and is effective in almost any size room. Depending on dust conditions and build-up, you may need to occasionally clean the bulb a...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category