Login:
Votes - 2, Average rating: 4.5 ( )

User manual Broan, model ERV90HC

Manafacture: Broan
File size: 2.29 mb
File name: 881c95f0-9f67-4237-a711-64bb1016a0c1.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Then, slide the bottom metal screen to the dual exterior hood. See illustration beside. *Patent pending 3.8.3 LOCATING THE DUAL EXTERIOR HOOD The dual exterior hood must be installed at a minimum distance of 18 inches (457 mm) from the ground. See illustration beside. 3.8.4 CONNECTING TANDEM® TRANSITION TO THE DUAL EXTERIOR HOOD 1. Using a jig saw, cut a 6’’ diameter hole in the exterior wall and insert the Tandem® transition through this hole. 1) Exhaust air to outside duct 3. INSTALLATION (CONT’D) VJ0025 VJ0022 VJ0023 VJ0024 1 2 3 4 EXHAUST AIR TO OUTSIDE DUCT ON TOP VO0024 WARNING Make sure this hood is at least 3 feet (0.9 m) away from any of the following: • High efficiency furnace vent. • Any exhaust from a combustion source. • Gas meter exhaust, gas barbecue-grill. • Garbage bin and any other source of contamination. 010 ! VD0083 18'' (457 mm) VD0084 1 CAUTION The Tandem® transition must be inserted in such a way that the Exhaust air to outside duct will be located on the top. - 14 - 3.8 INSTALLING THE TANDEM® TRANSITION KIT (CONT’D) 3.8.4 CONNECTING TANDEM® TRANSITION TO THE DUAL EXTERIOR HOOD (CONT’D) 2. Join the end of the Tandem® transition to the rear of the exterior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape. 3. Using 4 #8 x 11.2” screws, mount the the exterior backplate to the exterior wall. Seal the outline with caulking. 4. Snap the assembled exterior hood on its backplate and secure with 2 provided screws (#8 x 3.4” long). 3. INSTALLATION (CONT’D) VD0085 CAUTION The exterior backplate must be installed with the word «TOP» pointing upward. Xmas tree pin VD0086 VD0087 screw - 15 - 3. INSTALLATION (CONT’D) 3.9 INSTALLING 2 EXTERIOR HOODS Choose an appropriate location to install the exterior hoods: • There must be a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination • There must be a minimum distance of 18 inches (457 mm) from the ground Make sure the intake hood is at least 6 feet (1.8 m) away from the following: • Dryer exhaust, high efficiency furnace vent, central vacuum vent • Gas meter exhaust, gas barbecue grill • Any exhaust from a combustion source • Garbage bin and any other sources of contamination Refer to figure below for connecting insulated ducts to the exterior hoods. An ‘’Anti-gust intake hood’’ should be installed in regions where a lot of snow is expected to fall. VD0028 TAPE AND DUCT TIE OPTIONAL DUCT LOCATION EXHAUST HOOD INTAKE HOOD 18’’ (457 MM) 18’’ (457 MM) 6’’ O (152 MM) 18’’ (457 MM) 6’ (1.8 M) 6’ (1.8 M) - 16 4. CONTROLS 4.1 INTEGRATED CONTROL All units are equipped with an integrated control, located under the unit, in front of the electrical compartment. Use the push button (1) to control the unit. The LED (2) will then shows on which mode the unit is in. WARNING Risk of electric shock. Before performing any maintenance or servicing, always disconnect the unit from its power source. AVERTISSEMENT Danger d’electrocution. Debranchez toujours l’appareil avant d’entreprendre des travaux d’entretien ou de reparation. CAUTION Unscrew both screws to open the electrical compartment. To completely remove, detach from its retention wire inside. ATTENTION Devisser les deux vis pour ouvrir le compartiment electrique. Pour retirer completement, le detacher de son fil de retention interieur. No light OFF or remote controled Amber light LOW speed Green ligh HIGH speed Blinking light See User Manual Sans lumiere Arrete ou controle par controle mural Lumiere ambre Basse vitesse Lumiere verte Haute vitesse Clignotant Voir guide d’utilisation VD0182 1 2 Refer to table below to see how to operate the unit using its integrated control. PRESS ON PUSH BUTTON LED COLOR RESULTS ONCE AMBER UNIT IS ON LOW SPEED TWICE GREEN UNIT IS ON HIGH SPEED THREE TIMES NO LIGHT UNIT IS OFF If a problem occurs during the unit operation, its integrated control LED (2) will blink. The color of the blinking light depends on the type of error detected. Refer to Section 11 Troubleshootingon last page for further details. 4.1.1 BOOT SEQUENCE The unit boot sequence is similar to a personnal computer boot sequence. Each times the unit is plugged after being unplugged, or after a power failure, the unit will perform a 30-second booting sequence before starting to operate. During the booting sequence, the integrated control LED will light GREEN or AMBER for 5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED for the rest of the booting sequence. During this RED light phase, the unit is checking and resetting the motorized damper position. Once the motorized damper position completely set, the RED light turns off and the booting sequence is done. NOTE: No command will be taken until the unit is fully booted. 4.2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS For more convenience, this unit can also be controlled using an optional main wall control. NOTES: 1. The integrated control must be turned OFF to use an optional main...

Other models in this manual:
Air Cleaners - HRV90H (2.29 mb)
Air Cleaners - HRV90HS (2.29 mb)
Air Cleaners - ERV90HCS (2.29 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category