• Confirm that the Damper Switch (1) is in the ON position. • Check to make sure the system is on by pressing the Mode Button (2). • Make sure that all bags have been removed from the filters. Decreased airflow • It should be noted that the air entering the room is designed to be at a low flow rate to prevent drafts. • Confirm that nothing is blocking the air inlet and outlet. • If “SERVICE” is displayed and the performance bars are low, the filters need to be cleaned. See Routine Maintenance Instructions. • Check the condition of the filters. See Routine Maintenance Instructions. • Check to make sure that the foam seal- window Drafts around ing system is correctly installed. • The leftover foam segments can be used to seal any remaining openings. Routine Maintenance The Bionaire® Air Exchange System is easy to use and maintain. It includes filters that remove dust from air that is circulated through the system. These filters will need to be cleaned or replaced with use. The Service Indicator bar graph on the display (6) shows when service is needed. The Service Indicator bar graph decreases - and when the bars disappear, the filters need to be cleaned. The average duration between cleanings is about three months. WARNING: Do not attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. This unit contains no user serviceable parts. Only qualified personnel should perform servicing—other than what is described in this manual. About the Filters There are three black washable filters installed in the Air Exchange System. Each has a single tab that locks them into the unit. See Figure 18. There is one two-tab filter installed in the Air Exchange System. This will either be a black washable filter or a white disposable Electrostatic filter. The Electrostatic filter removes smaller particles from the circulating air. See Figure 19. PERFORMING MAINTENANCE 1. Confirm that the Service Indicator bars (6) no longer illuminate and the word "SERVICE" displays. This signals that maintenance is required. 2. Turn off and unplug the unit. 3. Remove the Air Exchange System from the Window Sealing Frame: See Figure 20. • Grasp each side of the Air Exchange System and gently pull it toward you. • Place the unit on a clean, level surface. 4. Remove the front grill. See Figure 21. 5. To remove the rear grill: See Figure 22. • Put the unit with the face down on the surface. • Place your thumb under the opening in the rear grill and pull up. One side of the grill will lift up and you will be able to slide the grill out. 6. Remove the black filters from openings #2, #3, and #4. Gently wash these filters with mild soapy water. Rinse in warm running water. Shake off excess water and allow to air dry completely. See Figure 23. Opening # 2 Figure 24 Opening # 1 Figure 18 Figure 19 Figure 21 Figure 23 Opening # 3 Opening # 5 Opening # 4 Figure 20 Figure 22 7. Remove the filter from opening #1. If it is a white electrostatic filter, discard it and replace with a fresh filter. Call 1 (800) 253-2764 to order replacement filters. See Figure 24. 8. If it is a black washable filter, clean it as described in step 6. 9. Remove the rubber Vacuum Plug from opening #5. See Figure 25. 10. Using a vacuum with a hose and a crevice tool, GENTLY vacuum the dust from the core by accessing openings #2 and #5. See Figure 26. CAUTION: Avoid applying pressure or scraping the surface of the core with the crevice tool as this may damage the core and decrease performance of the Air Exchange System. 11. Replace the rubber Vacuum Plug in opening #5. See Figure 25. Figure 25 Figure 26 12. After the filters are completely dry replace the three black filters over openings #2, #3, #4. 13. Insert a clean, dry black filter or a new white electrostatic filter over opening #1. 14. Clean the rear grill with warm soapy water. (Not dish washer safe). Dry with a soft cloth. 15. Remove dust from the front grill with a small soft brush or cloth. 16. Wipe down the rest of the unit with a clean, damp cloth. WARNING: DO NOT IMMERSE THE AIR EXCHANGE SYSTEM IN WATER. 17. Reinstall the rear grill: See Figure 27. • Put the unit with the front grill face down on the surface. • Place the grill on the rear of the unit with the thumb opening toward the bottom (power cord side) of the unit. • Gently press down on the edges of the grill until all edges are securely latched. 18. Put the unit on the table in the normal position and replace the front grill. See Figure 28. 19. Slide the Air Exchange Unit into the Window Sealing Frame and push until it locks in place. Figure 28 Figure 27 20. Insert the electrical plug into the outlet and turn the unit on. 21. Reset the service indicator by inserting the tip of a paper clip into the Service Reset Hole (5) and gently pressing the button inside the hole. 22. The Service Indicator bar graph should reappear. Replacement Filters Order these filters by calling 1 (800) 253-2764 Filter Part Number...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category