manual abstract


Remember that ambient temperature must be 180C or higher in order for the appliance to work. In this operation function, room temperature rises slightly. Air purification The air inside the room (ventilation) is circulated through a filtering system when the appliance is set to this function. The appliance comes with a basic filter (already fitted on the appliance) and a purifying filter (except on models PAM0520) to be fitted by the user-See “Fitting the purifying filter (double active)”- against: - Pollen, bacteria and dust. . Put the air expulsion tube in the same position as for dehumidification. . Lift the air director on the top of the appliance. This air director is not installed on the appliance on PAM0530 models. See figures 25 and 26 in “Heating”. . Remove the diffusion duct and set the air expulsion tube to the position shown in ....... fig 22. . The expulsion tube may also be totally dismantled if desired. . Plug the appliance into the mains electricity supply. . Set the control knob to the dehumidification function depending on the model of your airconditioning appliance. . Models with electric heating ; other models . 29 Instructions for Use Fig. 23 Fig. 21 Fig. 22 . Lift the air director on the top of the appliance. This air director is not installed on the appliance on PAM0530 models. See figures 26 and 27 in “Heating”. . Plug the appliance into the mains electricity supply. . Set the control knob to the air-purification function Fig. 24. Fig. 24 30 Instructions for Use . Select the heating function, Fig. 27. . Set the thermostat to the desired temperature. When this temperature is reached, the appliance turns itself off automatically. It comes back on again when the temperature drops 2-3.C. Warning! Do not cover the air intakes or outlets on your appliance! . When the appliance or the model is fitted with optional filters, we recommend that these be left on regardless of the function selected (cooling, dehumidification, air purification) in order to purify the air more effectively. Note: Due to the internal configuration of the PAM0520 models, air is also expelled outdoors when the appliance is set to the ventilation function. In order to reduce the noise produced, it is recommended that you remove the air expulsion tube. Heating (only on PAM0530) When set to position , the appliance heats the air in the room until the temperature set by the user is reached. The air in the room is purified at the same time. . Plug the appliance into the mains electricity supply. . Put the air expulsion tube in the same position as for dehumidification. . This air director is not installed on the appliance on PAM0530 models. The manufacturer recommends that an air director be previously installed in order to distribute the air flow better. The director is fitted as shown in the following figures. 20. 30. 20. 30. Fig. 25 Fig. 26 Fig. 27 31 Cleaning and Maintenance Cleaning the appliance . For safety reasons, you should unplug the appliance from the mains electricity supply before cleaning. . The appliance can be cleaned with a cloth or sponge, slightly warm water and a mild detergent. . Never use hot water (more than 40.C), bleach, petrol, acid, scouring pads, brushes or strong detergents. Prevent water from entering the appliance. . Do not clean the appliance with a water hose or compressed air. Cleaning and changing the purifying filters Press the side tabs, (Fig. 28, 1.), on the front flap of the appliance and pull it open (it is not necessary to remove it), (Fig. 28, 2.). The flap is fitted with a stop and can be opened up to this point without risk of falling. All models are fitted with a basic filter which needs to be cleaned regularly, Fig. 29. The filter is accessed by pressing the tab at the top and removing it from its housing, Fig. 30. The filter is cleaned under a cold tap, dried and replaced. a Washable basic filter 20. 30. Fig. 28 Fig. 29 Fig. 30 Warning! Do not try to clean the basic filter in a dishwasher. The plastic on the basic filter is not suitable for dishwashers and is unable to withstand the high temperatures involved in washing programmes. It will deform and may even break. The purifying filter supplied with the appliance (according to models) is to be fitted by the user (See “Fitting the purifying filter (double active”). The purifying filter further purifies the air in the room which passes through the appliance. When the purifying filter is fitted, the appliance’s cooling capacity may drop slightly. This is particularly the case when the filter is saturated or damaged. It is, therefore, recommended that you check and change the filter at least once a year. (These accessories are available for purchase from the Manufacturer's Official Technical Service and authorised distributors). See “Description of accessories”. Fitting the purifying filter (double active) • Check that the purifying filter is fitted in the positioner. If it is not, fit as shown on Fig 31 Fig. 31 32 Cleaning and M...

Other models in this manual:
Air Cleaners - PAM0520/02 (12.55 mb)
Air Cleaners - PAM0540/01 (12.55 mb)
Air Cleaners - PAM0540/02 (12.55 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category