Login:
Votes - , Average rating: ( )

User manual Whynter, model ECO PURE PAF-101

Manafacture: Whynter
File size: 436.81 kb
File name: WhynterEcoPurePersonalAirPurifierPAF-101InstructionManual.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait


Other manuals for this model:

manual abstract


Any other use will void the warranty 11. Do not try to disassemble, modify or repair the appliance by yourself. 12. Do not use the appliance upside down or its side. 13. Do not block the air intake and air outlet. 14. When positioning the appliance, ensure that there is at least a 6” clearance around the appliance. This allows for adequate ventilation. 15. If used with a humidifier, please keep this appliance away from the humidifier. 16. Never use harsh detergents or solvents to clean the appliance. 17. Do not operate the appliance without installing the filters. 18. Do not wash and reuse the Whynter HEPA filter. HEPA filters should only be replaced, not cleaned. Technical Data Product size 11”L x 11”D x 2.6”H Input voltage AC 100-240V / DC12V Airflow High: 45m3/h / 26.5cfm Low: 25m3/h / 15cfm Air Purification System Pre-filter Activated carbon filter HEPA filter Photocatalyst filter UV Lamp Weight 2.5 lbs Noise <45db Power 8W Coverage Area 150 Sq. Ft. PARTS OVERVIEW Main Unit 6 ONE TOUCH OPERATION ON/OFF: Turns the air purifier on and off. When the air purifier is on, the green light comes on. When the air purifier is off, no light comes on. SPEED: The default fan speed is Low (green light). Press the SPEED button to change to High fan speed (red light). Press the SPEED button again to change the fan speed to LOW (green light). FILTER & SCENT MAINTENANCE Lift up the three hinges at the back of the air input cover and pull it backward to remove the cover. Pre-filter: Remove the washable pre-filter. Rinse the pre-filter in warm water. Do not wash it in a washing machine or dish washer. Do not use water hotter than 100F degree. When the pre-filter is completely dry, place it back to the air purifier. Activated Carbon Filter & HEPA Filter: Remove the Activated carbon filter and the HEPA filter and replace with new ones. The Activated carbon filter and HEPA filter needs to be replaced every 2,000 working hours. The higher level of pollutants, the 7 shorter the lifespan of the filter. Dispose of the old HEPA and carbon filters and do not reuse. Please contact Whynter’s service department at service@whynter.com to order replacement filters. Photo catalyst filter: The Photo catalyst filter needs to be replaced after 6 months of working hours. Please contact Whynter’s service department at service@whynter.com to order replacement filters. Scent replenishment: Remove the scent sponge, drop one to two drops of your favorite scented oil to the sponge and put it back into the unit. CLEANING & MAINTENANCE The surface of the air purifier should be cleaned at least once a month or more often depending on the air quality. • Use a clean, dry cloth to wipe the external surfaces. • Use a damp cloth to remove stubborn stains and dirt build up. • Clean the air inlets and outlet with a dry cloth or a vacuum cleaner. • When dismounting or mounting the front cover, please be careful not to break the hinge. Service time of each filters are as follows: Pre-filter: 1500 hours Activated carbon filter: 2000 hours HEPA filter: 2000 hours Photo catalyst filter: 4500 hours UV lamp: The average service life of UV lamp is 3-5 years. Do not replace the UV lamp on your own, it should only be changed by a qualified technician. Scent freshener: Add scent as desired. TROUBLESHOOTING Trouble Check list Solution Unit does not start There is a power supply failure The air input cover is installed properly Ensure the air purifier’s power supply is securely in the unit and the power outlet has power Install the cover properly The air purifier is noisy and vibrates The unit is not level Ensure the unit sits on a hard and level surface. Do not place the unit on carpets. Odor and smoke are not removed Filters are dirty The unit is unable to circulate air Clean or replace filters Install unit in a place where air is able to circulate Air does not flow from the unit Air inlets maybe obstructed Ensure the air inlets are not obstructed 8 ONE YEAR LIMITED WARRANTY This WHYNTER air purifier is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your WHYNTER air purifier prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to one year, customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim to Whynter LLC. Please package the air purifier carefully in its original packaging material to avoid damage in transit. Please retain the original box and packaging material. Under this warranty, Whynter will repair or replace any parts found defective. This warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will be the responsibility of the original owner of the unit. THIS WARRANTY DOES NOT COVER: • Filters • Acts of God, such a...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category