|
manual abstract
By reformingmolecules,PlasmaWave TM technology can reduceodors, as well as VOCs (chemical vapors). It is also effectlve at reductngairbornemicroorganisms--bacteria and viruses. The PtasmaWaveTM technologyis harmless and the OH molecule only lives for a nanosecond whineit reforms surrounding molecules. Most importantly--unlike old style iontechnology-- PlasmaWave TM does not produce high levels of ozone as a by-product. When combinedwith a fan-and-filter air-cleaning system, PtasmaWave TM offers an effective and efficientway of cleaning the air of unwanted pollutantsincludingdust, smoke, and pollen, as well as VOCs, allergens,micro-organisms, and odors° Model RoomSize PowerSupply Power Rate ,L, ......... Fan Speeds Display Control Type Remote Control Air Quality Sensor , ,,, , H ,i,,,,,,i Light Sensor ....... L , ,'1,, " .... '"'' AHAM Certified UL Listed Sanitized m Treated Energy Star Qualified Check Filter Indicator Cleaning System -Carbon Pre-Filter -True HEPA Filter . PlasmaWave m CADR Unit Size (inches, WxH) Unit Weight (tbs) 85150 150 sq, ft, AC 120V!60(Hz) Low 4W, Turbo 40W 4 Speeds Digital AutofManua! No Yes ,,, ,,, , Yes Z ....... _-_ Yes Yes Yes Yes Yes Yes Yes Yes ....., .... ,,,_. Smoke/Dust/Pollen 981981103 8,27 x 18o50 x 13.78 11.15 85300 1300 sq, ft. AC 120VI60(Hz) Low 4W, Turbo 60W ..... 4 Speeds Digital AutotManual Yes Yes Yes Yes Yes IYes Yes Yes Yes Yes Yes r_' J,= SmoketDust/Potten 197/197/214 866 x 21o65 x t6.,30 13.95 85450 i450 sq, fl, AC 120Vt60(Hz) Low 11W, Turbo 110W _,,,,,,, .... 4 Speeds Digital Auto/Manual Yes Yes Yes ..... i lll,i ....................... Yes Yes ............................ . = Yes I Yes Yes Yes Yes Yes SmokelDust/Pollen 29!/298!343 10.24 x 25.59 x 17.,32 19.40 Set-Up Procedure 1.Remove protective film from the control panel. 2. Remove the front panel by pulling gently from the lower portion of the panel, Do not force; the panel should remove easily, 3_Remove the plastic frame from the unit. 4, Remove the True HEPA Filter and remove the plastic wrapper from the filter,_ O 5. Install the True HEPA Filter with the arrow showing °air flow" pointing in toward the back of the air cleaner; the white tabs at the top and bottom of the HEPA filler will poini out to the front of the uniL 6_Open the resealable plastic bag containing the Carbon Pre-Filters and remove one filter. Reseal the plastic bag to maintain the freshness of the remaining filter. O 7Anstall the Carbon Pre-Filter onto the plastic frame by pushing against six =hook and loop" squares on the back of the frame. (Diag_ 7A) 8,Install the plastic frame by inserting tabs _) up into the air cleaner and gently pushing in at the bottom tab until the frame fits into place snuggly, 9.Replace the front panel by hooking the panel on the top of the unit, Swing the panel in by pushing gently on each side of the unit and then lock it into place. 10. Plug the power cord into a wall outleL 11. Press and hold the POWER button until a short =beep" sounds_ 12oThe air cleaner will take 3-4 minutes to calibrate the AIR QUALITY sensor, During @ this time the sensor lights will flash on and off. Once the sensor has calibrated, the lights will stop flashing and the unit will begin in AUTO mode. @ !3,Remove tab from remote control (85450185300 only)_ O Note: For best results and to maximize air flow: • Place unit at least 2 feet away from the wall • Place the unit away from drafty areas, as O the sensors may not react accurately, • Do not place near curtains, furniture, or other items that might inhibit air flow_ • Place the unit on a stable surfacer 7 B5150 85300185450 A, AIR QUALITY SENSOR: Automatically monitors the air quality level and adjusts fan speed accordingly+ B. CHECK FILTER INDICATOR: The indicator will signal when to replace the True HEPA Filter, C. RESET FILTER: Resets the CHECK FILTER indicator light. D. AUTO: Changes the fan speed to AUTO. E. PLASMA INDICATOR: Displays the PLASMA activity. (See page 2 for PtasmaWave TM Technology) R AIR QUALITY LEVEL INDICATOR: Displays the current quality of the air. G. FAN SPEED INDICATOR: Displays current fan speed setting. H, FAN SPEED: Once the machine is on and inAUTO mode, switch to manual operation by pressing FAN SPEED button on the unit. J. POWER BUTTON: Turns the unit on and off. K. LIGHT SENSOR: When in AUTO mode, this keeps the control panel lights dim and will not allow the fan to increase above QUIET speed when the room is dark. AUTOMATIC OPERATION: When in AUTO mode, the air cleaner will automati + cally sense the amount of impurities in the air and adjust the fan speed accordingly_ When the unit is first turned on it will default to AUTO mode° MANUAL OPERATION (Adjusting the fan speed): Once the unit is on, switch to manual operation by pressing the UP & DOWN arrow buttons on the remote control or the FAN SPEED button_ Once in manual operation, the fan speed will not aulomaticalty adjust to the air quality or light level. , QUIET, MEDIUM, HIGH: These levels are re...
Other models in this manual:Air Cleaners - PLASMAWAVE 85150 (2.98 mb)
Air Cleaners - PLASMAWAVE 85450 (2.98 mb)