Login:
Votes - 3, Average rating: 4 ( )

User manual Lifebreath, model Lifebreath TFP3000HEPA

Manafacture: Lifebreath
File size: 98.78 kb
File name: 0f7de47f-2037-2b24-216e-a2667f91e843.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. C US * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to change without notice. TFP-3000 TYPE 1 INSTALLATION TFP Directly Connected to Forced Air Heating System 1. Install 7” port collar (provided) on top and bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8” screws (provided). 2. Remove protective backing from pieces of foam and stick them to the 4 corners of the TFP on the side being mounted against the plenum. 3. Remove the 4 mounting bolts from the back of the TFP cabinet. (Fig. 1) 4. Attach top and bottom mounting brackets (provided) vertical to the TFP cabinet and reinstall mounting bolts. 5. Lift the TFP into position. Edge of TFP must be positioned on plenum to allow clearance needed for latches. 6. Install the (4) 8/32” X 3/4” mounting screws (provided) through the brackets and into position. Tighten and secure. 7. TFP should now sit securely against the plenum with the foam in between. 8. Cut 2 - 7” holes in the plenum. Install ducting to join TFP to the return air plenum (Fig. 2). TFP TFP air cleaner TFP TFP Figure 1 NOTE: Do not support the weight of the TFP on the duct. Duct must be open and not pinched. NOTE: Due to possible noise transfer through the duct system, it may be preferable in some situations to hang the TFP a short distance from the plenum, and connect by running flexible ducting between them. Four nylon hanging straps are provided for this option. Install plate here Mounting bracket Foam gaskets Air Flow Supply Plenum FURNACE T F P Cold Air Return Air flow direction 7" port collars Access door Power supply Mounting bracket Ducting (not included) Clean (filtered) air port 1" Height Figure 2 Type 1 Installation * Direct connect to furnace/air handler return, or hang separately and connect to plenum with flexible ducting. 2 TYPE 2 INS...

Other models in this manual:
Air Cleaners - Lifebreath TFP3000 (98.78 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category