Login:
Votes - 2, Average rating: 4 ( )

User manual Carrier, model INFINITY 2020

Manafacture: Carrier
File size: 1.39 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Air Purification Cartridge (x1) (x2) A07111 Fig. 3 --- Infinityt Air Purifier Components GAPAB 3 INSTALLATION Step 1 —Check Infinityt Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts. ! CAUTION a. Carefully remove all items from the box. Step 2 —Identify Mounting Location a. Identify a mounting orientation for the Infinityt Air Purifier in the return air duct (see Fig. 4). b. Ensure airflow direction through the InfinitytAir Purifier matches the arrows on the face of the air purifier cartridge. The Infinity Air Purifier or door can be rotated 180_ to accommodate the cabinet orientation. c. The location of the InfinitytAir Purifier should be readily accessible. Enough room should be provided for periodic replacement of the air purifier cartridges. ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death. Only a trained, experienced service person should install the Infinityt Air Purifier. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. Tag disconnect switch with lockout tag. ! WARNING Upflow Horizontal Downflow Airflow A06374 A06381 Airflow Airflow A06516 Fig. 4 --- Infinityt Air Purifier Cabinet Orientation GAPAB 4 Step 3 —Mount Cabinet a. Turn off power to the heating and cooling system. b. Remove the existing fan coil filter and discard. Excessive systemstatic pressuremay result if the InfinitytAir Purifier is used with other filtration devices. c. Remove the air purifier cartridge and enhancement module from the Infinityt Air Purifier cabinet. d. Position the cabinet between the fan coil and return air duct (see Fig. 4 and 5). A transition duct may be required. NOTE: The fan coil cabinet screws holding the filter rack should be used to attach the air purifier cabinet. e. Gasket tape between the fan coil and the air purifier cabinet is already factory installed. f. Mounting holes are provided for fan coil attachment. g. Use return duct adapters provided to attach return ductwork (See Fig. 6). h. Seal seams with tape or caulking after the Infinityt Air Purifier cabinet has been secured. ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch. ! WARNING UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage. Cabinets will support a maximum weight of 400 lbs when installed beneath a vertical fan coil or air--handling unit. When setting fan coil on cabinet, do not drop it into place. Position the fan coil correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components. ! CAUTION Mounting Cabinet Vertical Mounting Cabinet Horizontal Return Duct Adapters (x4) Return Duct Adapters (x4) A06389 A06388 Fig. 5 --- Mounting Infinityt Air Purifier Cabinet for Fan Coils A06392 Fig. 6 --- Use of Return Duct Adapters GAPAB 5 Step 4 —Wiring a. Ensure power has been removed from the heating and cooling system. b. Turn the Infinityt Air Purifier power switch off. c. Connect the power cord and the flow sensor cord to the power supply connector and the flow sensor connector (see Fig. 7 and Fig. 8). NOTE: The power cord can be routed through the opposite side of the cabinet. Zip ties have been enclosed to secure the power cord to the side of the power supply. NOTE: Cable connector and block--off plates will need to be removed and re--installed if the power cord is re--routed. Screws on the cable connector clamp should be tightened to 9 in. -- lbs. torque. NOTE: The Infinityt Air Purifier is to be powered by 208/230Vac/60 Hz. NOTE: The Infinityt Air Purifier should only be powered when airflow is present. An airflow sensor is factory--installed (See Fig. 2 and Fig. 11). In order to bypass the airflow sensor, use the special bypass jumper included in the parts bag. With the bypass jumper in place, the air purifier will be on at all times when connected to electrical line power (see Fig. 10). d. Attach the quick connect terminals to the fused power connector leads (in parts bag attached to power cord) and connect to incoming field power. Attach the ground ring to fan coil chassis ground. (See Fig. 10.) ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death. Before installing or servicing system, always turn off main power to system. There may be more than 1...

Other models in this manual:
Air Cleaners - INFINITY 1620 (1.39 mb)
Air Cleaners - INFINITY 1620 (1.39 mb)
Air Cleaners - INFINITY 2420 (1.39 mb)
Air Cleaners - INFINITY 2020 (1.39 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category