manual abstract


These include tobacco smoke, household dust, pet dander and pollen. *Tested and listed by the Underwriters Laboratories, Inc. HIGH, MEDIUM AND LOW SPEED SETTINGS For optimum air filtration, operate your Holmes® air purifier continuously on the MEDIUM (2) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select the LOW (1) setting. When high levels of air pollution are present, select the HIGH (3) setting to quickly circulate and filter the room air. FILTER CHECK INDICATOR The filter indicator light eliminates guesswork by letting you know when it is time to replace the filters. BEFORE USE 1. Carefully unpack your Air Purifier. Select a firm level place where there are no obstructions to the air inlet or filtered air outlet. 2. Remove the air inlet grill and check if the filter is covered by a plastic bag. If it is, remove plastic bag before use and place filters into unit. Reinstall the air inlet grill. 3. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL. OPERATING INSTRUCTIONS 1. Plug into a 120V AC electrical outlet. The Filter Check Indicator light will blink three times to indicate that the feature has been activated. 2. Select the desired operating speed; HI (3), MEDIUM (2), LOW (1), by turning Speed Control Knob to the appropriate setting. For optimum air filtration, it is recommended to operate the air purifier continuously. Its rugged motor has been designed to give many years of use. 3. To release negative ions into the filtered air, press the ionizer button ( ) to ON and the outer ring of the button will illuminate in blue. NOTE: The ionizer will not work unless the unit is running. Fig. 1 B AC E D F GHI F F G H I I H G A. Control Panel F. Filtered Air Outlet B. Speed Control Knob G. HEPA-Type Filter C. Filter Reset Button H. Washable Foam D. Filter Check Pre-Filter Indicator Light I. Air Inlet Grill E. Ionizer Button CLEANING/MAINTENANCE INSTRUCTIONS 1. Turn the air purifier off and unplug it before cleaning. 2. The outside of the air purifier can be cleaned with a soft, clean dampened cloth. 3. The air inlet grill (reference Figure 1) can be removed and washed in warm soapy water (not dishwasher safe). Dry before replacing in the unit. 4. The filtered air outlet can be cleaned of dust with a small, soft brush. 5. If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down. WARNING: Do not allow moisture to come in contact with the main housing of the air purifier. FILTER REPLACEMENT INSTRUCTIONS IMPORTANT: • DO NOT attempt to wash and re-use the HEPA-type filter. • If the filters are enclosed in plastic bags, remove them before use. NOTE: Every few weeks, check the condition of filters. Filter life will vary, depending on air quality and usage. Under normal conditions of continuous use, the HEPA-type filter will operate efficiently for 3-6 months. After approximately 4 months of operation, the Filter Check Indicator will light up to alert you to replace filters before further use. To replace your filter: 1. Turn off and unplug the air purifier. 2. Open the air inlet grill and examine the black foam prefilter. Remove any dust or lint, and wash in warm soapy water. Rinse, drip dry, and place back into grill inlet. 3. Remove HEPA-type filter from the unit by pulling it gently towards you and discard it. DO NOT attempt to clean the old HEPA-type filter. 4. Install the new HAPF30 HEPA-type filter into the unit. This model utilizes a hang tab and filter clips to insure that the filter is properly in place. Before Fig. 3 Fig. 2replacing the filter, make sure that the hang tab is securely in place. The clip can only be attached to the tabs on the filter one way. The filter clip should easily slide onto the filter hang tab with only a small amount of pressure. DO NOT use force while attaching the clip to the filter. (Fig. 2) 5. Align the clip on the side of HEPA-type filter with rails on the inside of the purifier unit. Gently slide the filter onto the rail. (Fig. 3) 6. Replace air inlet grill. 7. To reset the Filter Check Indicator, press and hold the button for 3 seconds. The Indicator light will blink three times and turn off. Filters can be purchased at a retailer near you, online at or by calling 1-800-546-5637. THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than theother). To reduce the risk of electric shock, this plug is intended to fit in apolarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician toinstall the proper outlet. DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY. HOL A HAP9240_HAP9412_HAP9424 MANUAL_10EM2.indd2 22 HOL A HAP9240_HAP9412_HAP9424 MANUAL_10EM2.indd Air Purifier Filter Quantity Filter Model Filter Model Number Needed NumberDescription HAP9240/HAP9412 1 HAPF30 A Filter HEPA-type Filter HAP9424 2 HAPF30 A Filter HEPA-...

Other models in this manual:
Air Cleaners - HAP9240 (567.68 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category