manual abstract


FEATURES Dual Position The air purifier can stand upright or lie on its side. Also designed to fit with its back flush against the wall. When positioning the unit, please be sure the air inlet grill, filters and air outlet are not blocked to ensure maximum airflow. Filter Window On the front grill, there is a small opening that will enable you to see your carbon filter at a glance. As it picks up dust and debris, the window will turn to gray indicating the air purifier is working and you may need to change the carbon filters. HEPA Filter Indicator When the HEPA filter is approaching the end of its useful life, the indicator light will turn red. When the red indicator light starts flashing, it is time to change the HEPA filter. Carbon Filter Indicator When the carbon filter indicator light turns yellow, it is time to change the carbon filter. Energy Star Rated This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA. US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product. The energy efficiency of each ENERGY STAR qualified model is measured based on a ratio between the model’s CADR for Dust and the electrical energy it consumes, or CADR/Watt. Timer The timer allows you to run your air purifier at your convenience, for up to 16 hours. To operate using the timer mode, at the control panel on the air purifier, turn the unit on and select a speed. To activate the timer, press the "+" and "-" speed buttons at the same time for approximately 3 seconds. The numbers in the display will begin flashing and the light will appear to indicate timer function is on. Push “+” or “-” button to cycle through the timer options (1-16). When you have reached desired hours that you want your air purifier to run, release finger from the button; the numbers will stop flashing, timer will be on, and the screen will revert back to displaying a speed setting. The air purifier will then operate for the selected period of time and shut off automatically. Speeds can be changed once the timer is activated by pushing the “+” or “-“ buttons. To view the time left to run once timer has been set, push the “+” and “-“ at the same time for 3 seconds. You can manually turn the air purifier off by pressing the ( ) button once. PRE-OPERATING INSTRUCTIONS NOTE: The front grill should not be removed when the unit is on its side. 1. After removing the unit from the box, take the plastic covering off the unit and properly dispose of it. 2. Lay the air purifeir flat on its back with the front / air intake grill pointing up. 3. Open the door of the air purifier by carefully placing fingers in indentation on the right side of the door and gently pull forward. 4. The carbon filters, which are packed in a plastic bag in the box, should be removed from plastic bag and then placed on each of the HEPA filters. The plastic tabs on the HEPA filter will hold the carbon in place (see Figure 1). 5. Replace the front grill by aligning tab on left hand side and swinging down. Gently press until front grill is firmly in place. IMPORTANT SAFEGUARDS F E ATURES SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include: 1. Read all instructions before using the appliance. 2. To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet. 3. If the filter is covered by a bag when shipped, remove plastic bag before use. 4. Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters. 5. To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water. 6. Close supervision is necessary when any appliance is used by or near children, or disabled persons. 7. Always unplug the air purifier before moving or cleaning the unit, opening the grill, changing the filters and whenever the unit is not in use. To disconnect the unit, be sure to pull the plug and not the cord. 8. NEVER drop or insert any objects into the openings of the unit. 9. Do not operate any appliance with a damaged cord or plug. If the motor fan fails to operate or the unit has been dropped or damaged in any manner, return appliance to manufacturer for examination and/or repair. 10. Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards. 11. DO NOT use outdoors. 12. NEVER place on a soft surface such as a bed or sofa as this could cause the unit to tip over and block the air inlet or outlet grills. 13. Keep unit away from heated surfaces and open flames. 14. DO NOT attempt to repair or adjust any electrical or mechanical functions on ...

Other models in this manual:
Air Cleaners - HAP756 (337.31 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category