manual abstract


Please retain these instructions after installation. Installed By: Phone: Installation Date: page 2 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. INSTALLATION Determine a suitable l 1. ocation on either the supply or return for the unit as shown in Figure 1. The unit must be mounted at least 3 feet from any flex duct type material. NOTE: Unit can only be mounted in a vertical position as noted on inside cover label. 2. Apply mounting template to air duct. (See Figure 2) 3. Drill 1.8" diameter mounting holes at positions indicated on template. (See Figure 2) 4. Using a 2" hole saw, drill out lamp hole as shown on template. (See Figure 2) 5. Drill a 7.8" inspection hole as shown on template. (See Figure 2) 6. Remove template. 7. Mount unit to duct using the 4 supplied sheet metal screws. (See Figure 3) Lamp Length Minimum Duct Width Volts Amps Hz Watts Max Air Temp .F Lamp Intensity at 1 meter Recommended Max Sq. Feet 12" 9 120/240 .5 60 30 150. 37.W/cm2 1500 18" 14 120/240 .5 60 30 150. 73.W/cm2 2000 28" 22 120/240 1.1 60 60 150. 105.W/cm2 3000 Figure 1 Figure 2 Figure 3 GENERAL INFORMATION This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition, nor for use in the mitigation, treatment, or prevention of any disease or condition. There are different size units available, depending on the square footage of your home. See chart below for determining your home’s needs. WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have units unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source. page 3 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. WARNING: Disconnect electrical power supply before wiring. Connect to a 8. n appropriate power source such as an AC power disconnect box or to a circuit breaker panel. (See Figure 8) 9. Determine length of wire and conduit necessary according to power connection and install wiring conduit and water tight connector as shown in example figure 4. (Supplied by installer.) 10. Remove wiring access cover to expose terminal block. (Figure 5) 11. Push power source wires through bushing in access cover then begin securing wires according to the wiring diagram in figure 8. (See Figures 6 & 7) 12. Replace access cover. 13. Group wires together and tuck in wire clip on right side of box. (See Figure 9) 14. Determine whether to use flat or angled bracket. (Refer to UV-Aire Configurations Section) Figure 6 Figure 7 Figure 8 Figure 9 Figure 4 Figure 5 Access Cover FLAT BRACKET INSTALLATION 1. Remove the two hex nuts and flat bracket from included bagged hardware. 2. Install the flat bracket and secure to the unit base with the hex nuts provided. (See Figure 10) ANGLED BRACKET INSTALLATION NOTE: For angled bracket mounting, refer to specifications outlined by Diagram A for mounting distances in the Angled Lamp Mounting Bracket Specifications. 1. Remove the two hex nuts and angled bracket from included bagged hardware. 2. Install the angled bracket and secure to the unit base with the hex nuts Figure 10 provided. (See Figure 11) The angle bracket may be mounted in 4 positions allowing the bulb to either be angled up and down or left to right, depending upon duct design. (Figures A-D) NOTE: Be sure to note location of lamp hole in bracket relative to unit base. Figure 11 Figure A Figure B Figure C Figure D LAMP INSTALLATION This unit is listed for use with Field Controls’ lamps ONLY. You will need to determine proper lamp selection based on duct size and desired configuration. (Refer to configuration table in this manual.) 15. Remove tag and alcohol from lamp. Wipe off lamp, being sure not to touch lamp with bare hands. The oils in your hands may cause the lamp to prematurely expire. 16. Insert lamp through hole in bracket until lamp is snug against the bracket. (See Figure 12) Figure 12 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 4 17 . Swing securing bracket over end of lamp and hand-tighten the provided wing nut on stud. (See Figure 13) 18. Plug ballast plug into end of lamp and reconnect power supply. (See Figure 14) 19. Flip the red power switch to the on position. (Light on switch should be on i...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category