Login:
Votes - 3, Average rating: 4.3 ( )

User manual Friedrich, model C-90B

Manafacture: Friedrich
File size: 1.66 mb
File name: 41ca89b1-d7aa-45e3-9541-d94f760fdf2c.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


2 CAUTION - Before Operation ........................................................................................................................................ 4 Operating Your Friedrich Air Cleaner ............................................................................................................................ 4 How Electronic Air Cleaners Work ................................................................................................................................ 5 Cleaning Important Precautions ...................................................................................................................................... 5 Cleaning the Pre-Filter ..................................................................................................................................... 5 Cleaning the Carbon Filter ............................................................................................................................... 5 Cleaning the Electronic Cell ............................................................................................................................. 6 Alternate Cell Cleaning Method........................................................................................................................ 6 Discoloration of the Cell ................................................................................................................................................ 6 Replacing the Cell in Cabinet ........................................................................................................................................ 7 Activated Carbon Filter .................................................................................................................................................. 7 Consumer Troubleshooting Guide ................................................................................................................................. 7 Troubleshooting Electronic Air Cleaner ......................................................................................................................... 8 Wiring Schematic .......................................................................................................................................................... 9 Major Components ........................................................................................................................................................ 10 C-90B Electronic Air Cleaner Component Parts List .................................................................................................... 11 Authorized Warranty Repair Stations ............................................................................................................................ 12 FRIEDRICH C-90B ELECTRONIC AIR CLEANER The Friedrich Electronic Air Cleaner is a self-contained console model consisting of a high voltage DC power supply, electronic cell, 3 speed fan, pre-filter and activated carbon post-filter in a rugged plastic cabinet. It is designed to remove dust, tobacco smoke, pollen, bacteria, and other airborne contaminants from the air. In just minutes, SPECIFICATIONS OPERATING TEMPERATURES This air cleaner is intended for use at temperatures normally found in conditioned, occupied spaces. ELECTRICAL RATINGS 115 Volt, 60 Hertz. INDICATOR LIGHT Located on the top access cover, next to 3-speed switch. Indicates air cleaner operating properly. INTERLOCK SWITCH Interrupts supply power to unit when access cover is opened or carbon filter is removed. WEIGHT 35 lbs. shipping weight 30 lbs. net weight you will notice improvements in your indoor air quality as your Friedrich air cleaner begins the job of removing the billions of irritating microscopic particles from your home or offi ce. The activated carbon post-filter also helps eliminate many objectionable indoor odors. DIMENSIONS Height Width Depth Cabinet 19" 15" 21 1/2" Cell 16" 12 1/2" 4 1/2" Pre-Filter 15 7/8" 12 3/4" 1/4" Carbon Filter 15 7/8" 12 3/4" 1/4" NOMINAL CURRENT AND POWER CONSUMPTION Power Supply 120 Volt, 60 Hertz CFM Amps Watts High Speed 390 .80 90 Medium Speed 280 .56 64 Low Speed 220 .41 47 CAUTION - READ BEFORE OPERATION • Remove the plastic cover from the activated carbon fi lter and install in unit. • Position the pre-filter at the rear of the unit (closest to the electronic cell) and the carbon filter at the front (where air comes out.) • Make sure the electronic cell is properly placed in the cabinet (airflow arrow on the end plate should be pointing toward the fan). • Make sure that the top cover and carbon air filter are securely in place. • This unit is equipped with a grounded plug for your protection against shock hazards and should be plugged directly into a properly grounded receptacle. • Electronic air cleaners should NOT be placed in any area where potentially explosive gases or vapors exist, nor should they be used in wet environments. These units should b...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category