|
manual abstract
Be sure to use the proper procedure for drilling porcelain or stainless steel. Special drill bits may be needed. Consult a qualified plumber for the proper procedure. CAUTION: When drilling in Stainless Steel, the edges may be sharp and could puncture the tube. Be careful to not cut yourself or damage the tube. 2. Remove the faucet body and base by turning the base counterclockwise. 3. Remove the butterfly bracket from the screw. Then insert the screw into the top of the base and reattach the butterfly bracket. 4. Align the gasket to cover the hole completely. Then place the butterfly bracket on the base into the hole. 5. Tighten the screw to secure the butterfly bracket to the underside of the sink top. The base should be firmly in place and should not wobble or turn. Base Sink Gasket Butterfly Bracket Screw 7 Installation Instructions INSTALL THE FAUCET (CONT.) 6. Feed the water tube up through the faucet base. Then push the tube into the fitting on the bottom of the faucet body. It should go in about 3/4.. Pull tube slightly to make sure it is secure. 7. Push the faucet body down into the faucet base and twist clockwise until it clicks into place. NOTE: You can install the faucet so the handle is on the right or the left side. If you want the faucet handle on the right, position the handle at the back of the faucet base before turning clockwise. If you want the faucet handle on the left, position the handle at the front of the faucet base before turning clockwise. 8. Locate the hole at the rear of the base. Insert set screw and begin to tighten by hand. Finish tightening with the allen wrench provided in the packet. Faucet Body Base Sink Gasket Toggle Screw Faucet Faucet Faucet handle on the RIGHT Faucet handle on the LEFT 8 Installation Instructions MOUNTING SYSTEM INSTALLATION Pick a location under the sink to mount the system. Location should be easily accessible, with clearance between the bottom of the filter canisters and the floor or bottom of the cabinet; any less will result in difficulty of removing filter canisters (see Fig. 5). Allow enough space on either side of the system for the tubing connections. SCREW INSTALLATION 1. Remove this template from the manual for easier installation. 2. The top of the template openings should be placed a minimum of 17 inches above the bottom of the cabinet or floor where the system is to be mounted (Fig. 4 and 5). NOTE: Any distance lower may result in filter canisters interfering with the floor when removed. 3. Tape template to wall, then mark the wall where the screws are to be installed. Install screws into the wall, leaving 3/16 inch clearance between the head of the screw and wall (drill pilot holes if needed) (Fig. 6). 5 inches 17 inches Template for screw hole pattern on back of filtration system Fig. 4 Bottom of Cabinet or Floor 17 inches 5 inches Screws Fig. 5 3/16 inch Wall Screw Fig. 6 9 Installation Instructions MOUNTING SYSTEM INSTALLATION (CONT.) Mounting System to Screws Installed in Wall 1. Remove shrink wrap from filter system. 2. Hang the system on the previously installed screws using the openings on the back of the unit (Fig. 7). 3. If the head of the screw will not slide into the upper slot, back out the screw by 1/4 turn and try again. 4. If the system is too loose when placed on the wall, tighten the screws by 1/4 turn and try again until a desired fit is achieved. Min. 17 inches 5 inches Fig. 7 10 Installation Instructions INSTALLING THE TUBING 1. Measure 3/4.from the end of each remaining piece of tubing (faucet end and inlet end) and mark with a pencil (Fig. 8). (Check for roundness, smoothness, cuts, nicks, flat spots and sharp edges. It may be necessary to recut the tubing.) 2. Locate fittings for tubing on bottom of manifold. 3. NOTE: Water flow is from left to right. Water inlet is on the left side and water outlet is on the right side. Failure to follow will result in water leaks when filter canisters are removed. 4. Push the tubing firmly into each fitting on the manifold until the line is flush with the fitting collar. (If the tubing is removed, re-cut the end, measure, mark and re-insert). Tubing must be fully inserted to avoid leaks (Fig. 9). (To remove tubing, depress and hold white collet; pull tubing out to remove.) 3/4. (19 mm) Fig. 8 INCORRECT INLETOUTLETInlet from supply valve Outlet to faucet 34" Engagement 3/4.(3/8.tubing) White Collet (DO NOT REMOVE) Insertion line Insert tubing Fig. 9 INSTALLING THE TUBING (CONT.) 5. Pull out slightly on tubing to ensure a good seal. 6. Install the other end of the tubing from the inlet side of the manifold to the feed water adapter. NOTE: Inspect the ends of the tubing to be sure there are no imperfections and that the end of the tubing is cut square. It may be necessary to cut the tubing again. INSTALL THE BATTERY 1. Remove the lens cover from the faucet base. Grip it from both sides and pull forward. 2. Install one CR2032 3V battery with the “+” side down into the battery tray....
Other models in this manual:Water Systems - GNSV70RBL (822.05 kb)