Login:
Votes - 4, Average rating: 4 ( )

User manual Baxi Potterton, model BAXI COMBI INSTANT 105E

Manafacture: Baxi Potterton
File size: 619.5 kb
File name: 248742.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Baxi Combi Instant 105e Gas Fired Wall Mounted Combination Boiler User’s Operating Instructions Natural Gas Baxi Combi Instant 105e G.C.No 47 075 09 Baxi UK Limited is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is designed into every Baxi product -products which fulfil the demands and needs of customers, offering choice, efficiency and reliability. To keep ahead of changing trends, we have made a commitment to develop new ideas using the latest technology -with the aim of continuing to make the products that customers want to buy. Everyone who works at Baxi has a commitment to quality because we know that satisfied customers mean continued success. We hope you get a satisfactory service from Baxi. If not, please let us know. The boiler meets the requirements of Statutory Instrument “ The Boiler (Efficiency) Regulations 1993 No 3083” and is deemed to meet the requirements of Directive 92/42/EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels: Type test for purpose of Regulation 5 certified by: Notified Body 0051. Product/Production certified by: Notified Body 0051. For GB/IE only. Baxi is a BS-EN ISO 9001 Accredited Company STANDARD SCOPE B.S. 6891 Gas Installation. B.S. 5440: Pt 1 Flues. B.S. 5440: Pt 2 Air Supply. B.S. 5546 Installation of hot water supplies for domestic purposes. B.S. 7074 Expansion vessels and ancillary equipment for sealed water systems. B.S. 5449 Forced circulation hot water systems. B.S. 6798 Installation of gas fired hot water boilers. IN AN EMERGENCY If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. Turn off the electrical supply and turn the selector switch on the facia box to the OFF position. 2. Using a suitable open ended spanner or screwdriver turn the square on the gas tap to the left to isolate the gas supply at the boiler (Fig. 1). 3. The isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 2). 4. Call your Service Engineer as soon as possible. “Benchmark” Installation, Commissioning and Service Record Log Book Please ensure that your installer has completed the Installation and Commissioning sections of the Log Book and hands the Log Book over. The details of the Log Book will be required in the event of any warranty work. Keep the Log Book in a safe place and ensure that the relevant sections are completed at each subsequent regular service visit. All CORGI registered installers carry a CORGI identification card and have a registration number. Both should be recorded in your boiler Log Book. You can check your installer is registered by telephoning 01256 372300 or writing to:1 Elmwood, Chineham Business Park, Crockford Lane, Basingstoke. RG24 8WG. Gas Tap Fig. 1 Fig. 2 Heating Flow, Heating Return and Mains Water Inlet Isolating Valves 1.0 Warnings 1.1 Safe Installation 1. The appliance is suitable for installation only in G.B. and I.E. and should be installed in accordance with the rules in force. For Ireland install in accordance with I.S.813 “INSTALLATION OF GAS APPLIANCES”. The installation must be carried out by a CORGI Registered Installer or other registered competent person and be in accordance with the relevant requirements of GAS SAFETY (Installation and Use) REGULATIONS most recent edition, the BUILDING REGULATIONS issued by the Department of the Environment, BUILDING STANDARDS (Scotland) (Consolidation) REGULATIONS issued by the Scottish Development Department and the LOCAL BUILDING REGULATIONS. Where no specific instructions are given, reference should be made to the relevant BRITISH STANDARD CODES OF PRACTICE and INSTALLATION SPECIFICATIONS. 2. This appliance must be installed in accordance with the manufacturer’s instructions and the rules in force, and only used in a suitably ventilated location. 3. Read the instructions before installing or using this appliance. 4. Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction. IMPORTANT - The addition of anything that may interfere with the normal operation of the appliance without the express written permission of Baxi UK Limited could invalidate the appliance warranty and infringe the GAS SAFETY (Installation and Use) REGULATIONS. 1.2 In case of gas leaks 1. If a gas leak is found or suspected, turn off the gas supply at the meter immediately and at the isolating valve on the boiler if possible. Contact your Installer or Transco (under 'Gas' in the phone directory). 1.3 Servicing your Appliance 1. For reasons of safety and economy your appliance should be serviced annually. Servicing must be performed by a competent person. Your Installer or British Gas Service will be able to advise you. 1.4 Electricity Supply 1. THIS APPLIANCE MUST BE EARTHED. 2. A standard 230V ~ 50Hz sup...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category