Login:
Votes - 2, Average rating: 4.5 ( )

User manual Bryan s, model DSH-20

Manafacture: Bryan s
File size: 574.99 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


With its all stainless steel spring loaded spray valve and second stage steam scrubber, the spray type deaerator is a good choice for all deaerator applications. Units are available with a complete range of boiler feedpumps and control options making them a total deaerator package with minimal amount of field assembly. Horizontal Tank Design Condensate Return and Water Make-up Inlet Internal Vent Condenser, Vent to Atmosphere _ r Steam Inlet \ / Nozzle Deaerator Scrubber Section I Non-Condensable Gases (0„ Co;) I Deaerated Water I Steam I Condensate Return and Water Make-up Vent to Atmosphere ■ Internal Vent Condenser Integral Tank Design Condensate Return and Water Make-up Inlet Pre-Heater Section Deaerator Scrubber Section Deaerator Outlet Nozzles Deaerator Outlet Nozzles Bryan Spray Type Deaerators — Horizontal and Integral Horizontal Tank Integral Tank Design *Note: Stand height varies depending upon pump specifications and job conditions. Dimensions are for reference only and may change without notice. Consult factory for certified dimensions. Specifications Model Capacity Dimensions in inches (cm) Pounds/hr (kg/h) Boiler hp (kW) Storage in gallons (liters) A Overall length B Overall width C* Overall height Horizontal Tank Design DSH-5 5,000 (2,268) 145 (1,422) 200 (757) 124 (315) 36 (91) 52 (132) DSH-10 10,000 (4,536) 290 (2,844) 200 (757) 124 (315) 36 (91) 52 (132) DSH-15 15,000 (6,804) 435 (4,267) 300 (1,136) 117 (297) 42 (107) 60 (152) DSH-20 20,000 (9,072) 580 (5,689) 400 (1,514) 120 (305) 48 (122) 64 (163) DSH-25 25,000 (11,340) 725 (7,111) 500 (1,893) 137 (348) 48 (122) 64 (163) DSH-30 30,000 (13,608) 870 (8,533) 600 (2,271) 156 (396) 48 (122) 64 (163) Integral Tank Design DST-35 35,000 (15,876) 1,014 (9,956) 700 (2,650) 143 (363) 48 (122) 104 (264) DST-40 40,000 (18,144) 1,159 (11,378) 800 (3,028) 156 (396) 48 (122) 104 (264) DST-45 45,000 (20,412) 1,304 (12,800) 900 (3,407) 141 (358) 54 (137) 110 (279) DST-50 50,000 (22,680) 1,449 (14,222) 1,000 (3,785) 171 (434) 60 (152) 120 (305) DST-60 60,000 (27,216) 1,739 (17,067) 1,200 (4,542) 177 (450) 60 (152) 120 (305) 1. High water level control 2. Low water level control 3. Make-up water control 4. Vacuum breaker 5. Temperature gauge 6. Pressure gauge 7. Overflow trap 8. Vent 9. Pump suction 10. Pump bypass 11. Chemical port 12. Drain 13. Sample port 14. High temperature condensate return 15. Gauge glass 16. Manway access opening * Not including the stand. BRYAN STEAM Bryan Steam LLC — Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone:765-473-6651 • Internet:Fax:765-473-3074 • E-mail: bryanboilers@iquest.net ©2000 Bryan Steam LLC 50-2517D...

Other models in this manual:
Water Heaters - DSH-10 (574.99 kb)
Water Heaters - DSH-15 (574.99 kb)
Water Heaters - DSH-25 (574.99 kb)
Water Heaters - DSH-30 (574.99 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category