User manual EverFocus, model EDSR-400

Manafacture: EverFocus
File size: 1.03 mb
File name: 31e09e2b-c23f-496f-b124-4d9aa12d8b51.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


(3) EVENT: Set the alarm and correspondent motion to the camera. NONE: no alarm or motion action is assigned to this camera. MOTION: If MOTION detection is active for this camera, the camera will be displayed, if motion is detected. After alarm record duration the monitor switches back to standard sequence or spot camera (depending on operation). A01 ~ A06: The camera will be displayed, if selected alarm input is active. Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column. ENTER Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 24 MENU 6.14 DISK SETTING MENU DISK SETTING MENU DISK USAGE HDD-1 HDD-2 SIZE (GB) : 160 160 RECORD POS : * 30.7% 0% PLAY POS : *30.7% 0% DISK RENEW: NO NO In the DISK SETTING MENU, we define (1) DISK USAGE: HDD-1, HDD-2 (2) SIZE: Applied HDD size. (3) RECORD POS: HDD usage rate, record position, “*”shows the active HDD (4) PLAY POS: current playback position, “*”shows the active HDD (5) DISK RENEW: Erase HDD-1, HDD-2 Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column. ENTER Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 25 MENU 6.15 SYSTEM SETTING MENU SYSTEM SETTING MENU PLAY WITH AUDIO-1 : ON PLAY WITH AUDIO-2 : ON For password Input, you may use the CH keys (Pic 1) or following function keys (Pic 2). PLAY SPEED : 50 IPS PASSWORD ENABLE : DISABLE PASSWORD LEVEL-2 : 222222 PASSWORD LEVEL-3 : 333333 MULTI-EVENT DWELL: 02 SEC Pic 1 SYSTEM UPDATE: NO LOAD DEFAULT: NO In the SYSTEM SETTING MENU, we define Pic 2 (1) PLAY WITH AUDIO: AUDIO-1, AUDIO-2 ON/OFF: Play back with or without audio. (2) PLAY SPEED: Set the playback speed. Maximum 60 (NTSC) / 50 (PAL). (3) PASSWORD ENABLE: Enable/Disable the password protection. Once you enable the password, the default value is Level-1 (Lowest level) for live view only (CH keys, MODE, SEQ and ZOOM buttons). Default: 111111 (4) PASSWORD LEVEL-2: (General): Live and Playback view. (Limited: MENU and CALL buttons, Event Log List and Display Setting). Default: 222222 (5) PASSWORD LEVEL-3 (Highest): All buttons and configuration. Default: 333333 Note: Press SELECT button for around 3 seconds to logout the system and return to level-1. (6) MULTI-EVENT DWELL: Define the dwell time when there are more than one event triggered at the same period. (7) SYSTEM UPDATE: Select YES/NO for updating system. YES: Download the update S/W into C.F card through your PC and insert the CF card into the slot on the front panel of DVR. Press ENTER key to start. Notice: After the system is successfully updated, please reboot the system. (7) LOAD DEFAULT: Select YES/NO to load factory default setting, necessary after update. 1 2 3 4 5 6 7 8 9 Turn the JOG dial clockwise or counter-clockwise to select the options. Press ENTER key to confirm the option and move to next column. ENTER Press CALL key to confirm the option and move to previous column. CALL Press MENU key to return to Main Menu, press again to leave Set up Menu. MENU 26 Recording 7.1 INSTANT RECORDING Press REC key to start continuous recording with setting of “NORMAL RECORD”. The recording rate and recording quality are set in the RECORD SETTING MENU. REC The LCD screen on the front panel of DVR will display as follows: 2003/11/23 REC HDD1 70% 21:56:47 50 IPS 21:56:52 Display shows operation status, active HDD, record position on active HDD, record frame rate ant current time. REC, Maximum 60 (NTSC) / 50 (PAL) fields will also show on the main monitor display if you press the DISPLAY key to show camera title and date/time. Press STOP key to stop recording. When the HDD is full, the machine will Stop recording automatically or Auto Overwrite STOP Since the DVR had Duplex feature, STOP key can be activated both in Playing back and Recording. In Duplex mode first STOP will stop playback, second STOP will stop recording. from the beginning of the HDD. It depends on the setting in RECORD SETTING MENU. 7.2 ALARM RECORDING When the ALARM OPERATION setting is “ON”, the DVR will automatically record when alarm occurs , and will automatically stops recording at the end of the alarm duration period. As example, we set ALARM RECORDING SPEED on 60 (NTSC) / 50 (PAL) field, the screen will show as below, A. REC (50IPS) DISK: 39 GB Instant recording and timer recording will stop when an alarm occurs. Please refer details in RECORD SETTING MENU (page 19). 27 Playing Back 8.1 NORMAL PLAYBACK (1) Playback Press the PLAY key to start playing back the stored image/audio from the last SEGMENT. PLAY NOTE: In Duplex mode (simultaneous record and playback) the playback speed is limited to 25 IPS. For real time display of 50 IPS records stop recording before starting playback. (2...

Other models in this manual:
Security Systems - EDSR-600 (1.03 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category