Login:
Votes - 2, Average rating: 4 ( )

User manual Panasonic, model WVCU161

Manafacture: Panasonic
File size: 864.33 kb
File name: WVCU161.PDF
Language of manual:enfr
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


o Line Selection Switch (LINE 4/2) This switch is used to select either Full-duplex (4-lines) or Half-duplex (2-lines) for the communication lines. !0 Data Selection Switch (COAX/RS485) This switch selects either multiplex coaxial data or RS485 data from control data with the camera site. !1 Video Output Connector (VIDEO OUT) Video signals from the camera are output from this connector. !2 Camera Input Connector (CAMERA IN) This connector accepts the multiplexed video and control data signal from the specified camera such as WVCS854, WV-CS654 or WV-CS604 or a specified receiver. !3 AC Cord !4 Power Switch (POWER ON/OFF) This switch is used to turn the power of the System Controller on and off. Note: Turning off this switch will not interrupt the power supply. Disconnect the AC cord or turn off the circuit breaker when the controller is not used for a long time. !5 Signal Ground Terminal (SIGNAL GND) SETUP The WV-CU161 can be programmed by setting switches or from the interactive Setup menu as described below. 1. DIP Switch Setting (See page 10) 2. Data Switch Setting For setting the mode of communication between the WV-CU161 and the combination camera. 3. Alarm Switch Setting For setting up the alarm terminal. Turn off the power before setting this switch. 4. Setup of WV-CU161 Display the Setup menu (see page 17) to setup the WV-CU161. Data Switch Setting Set this switch to specify the mode of communication between the WV-CU161 and a connected combination camera. • Coaxial Multiplex communication via a coaxial cable In this mode, control signals transmitted to the combination camera are multiplexed with the video signals. Allows control of a camera installed at a distance of up to 900 m (3 000 ft) from the WV-CU161 via a single coaxial cable (When using RG-59U, BELDEN 9259 or equivalent cable). • RS-485 site communication In this mode, control signals transmitted to the combination camera are separated into video signals and control signals. Allows control of a camera installed at a distance 1 200 m (4 000 ft) or more from the WV-CU161 via an interface unit such as an AV Codec. Note: Keep the power switch in the off position while setting each switch (DATA, TERM, LINE). The switch setting will not take effect if the power is on. Alarm Switch Setting Rear Panel RS485 DATA TERM LNE COAX RS485 4 2 ON OFF RT ABABG Coaxial Multiplex communication RS-485 site communication Set the 4 or 2 position according to the desired data line selection mode. Set to ON position in case of terminating. For Using Alarm Input/Output Terminal and Alarm Recovery Input/Output Terminal Place the Alarm Switch in the upper position for the following uses: • Connection with the Time Lapse VCR. • Transmitting the alarm signal to external devices. • Resetting the alarm signal from external devices. For Using Alarm Input Terminals 1-4 Place the Alarm Switch in the lower position to use alarm input terminals 1-4. This allows input of up to four alarm signals into the WVCU161. Also allows programming the alarm switch to activate four preset positions for a connected combination camera. Note: Keep the power switch in the off position while setting the alarm switch. The switch setting will not take effect if the power is on. ALARM RESET OUT ALARM IN RECOVER IN ALARM OUT ALARM IN 12G34 For using alarm input/output terminal and alarm recovery input/output terminal For using alarm input terminal 1-4 10 Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the system settings. The following setting procedure should be made by qualified service personnel or system installers. DIP Switch Setting Caution: Unplug the AC cord before changing any DIP switch setting. Removing the Bottom Cover for SW1 1. Take off the bottom cover by removing the two screws. CONNECTIONS SW1 SW1 lets you choose 0/5V or open collector (O.C.) for the alarm recover output signal. 0/5V: +5 V DC approx. 500 m sec. Open Collector (O.C.): 16 V DC 100 mA max. The initial factory setting is 0/5V. Remove two screws. Bottom Cover Panasonic SW1 SW1 O.C 0/5V NOR: White with Black border REV: Black with White border The initial factory setting is NOR. SW4 Confirm that SW4 on the board is set as shown below. This switch is used only for factory tests. Do not change this switch setting. SW100 SW100 lets you choose the mode for displaying characters on the monitor. Bit ON OFF 1 2 3 4 SW4 SW100 NOR REV Removing the Bottom Panel for SW100 1. Take off the side panels by removing the four screws. 2. Take off the bottom panel by removing the 8 screws. SW100 Remove four screws. Remove four screws. q w SYSTEM CONNECTION The WV-CU161 can be connected with a camera, a video monitor and a Time Lapse VCR. A typical connection example is shown below. Basic System Connection ALARM INPUT/OUTPUT (See page 14) WV-CS854 WV-CU161 Time Lapse VCR System Controller WV-CU 1 2 3 4 6 7 8 9 0 5 SHIFT OPERATE ALARM RESET RESET SUSPEND CAMERA S...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category