User manual Cooper Hand Tools, model 9448ES

Manafacture: Cooper Hand Tools
File size: 106.43 kb
File name:
Language of manual:enfr
Free link for this manual available at the bottom of the page



manual abstract


When Chime is on, the internal sounder chimes when the chime zones operate. Note that the Installer must program your chime zones. KEYPAD PA Your system may be programmed to allow you to start a Panic Alarm from the keypad (ask you Installer). If so, then press keys 1 and 3 together to start a Panic Alarm. AFTER AN ALARM To switch the bells off: Key-in your user code. The sounders will stop and the zone light(s) for the detectors that triggered the alarm will glow. Reset system: You must reset the system before it can be used again. Key-in your access code again. All the zone lights should go off. The system is now ready for use. Fire Alarm: The fire alarm is a two tone siren note from the internal sounder. Leave the building immediately and call the Fire Brigade. Do not go back into the building until it is safe to do so. Switch the alarm off and reset the system as described above. If you have trouble resetting the system make sure that the fire detector is not being triggered. Tamper or Panic Alarm: If you hear the internal sounder when the system is off then look at the control panel: If the Tamper light glows then key-in your user code to stop the sounder. Call your alarm installer for service. 4 496572 4 ? ??? 5 4 ? ??? 5 ? ??? Trigger Detectors (Not Panic Alarm) ? ??? 8 ? ??? Keypad shows most recent event. Earlier events. << >> Later events. If the Panic light (zone 6) glows then deal with the cause of the alarm first. Next, reset the panic button, then switch the alarm system bells off and reset the system (see above). TO TEST BELLS Make sure system is unset before starting the test. Key in 4 then ENTER followed by your user code. The internal sounders will operate for three seconds and then the external sounder and strobe will operate for three seconds. TO WALK TEST Key in 5 then ENTER, followed by your user code. The internal sounder gives a steady tone. Open and close the Exit/Entry zone and zones 1 to 4. (Open and close zone 5 if it is NOT a fire zone, and zone 6 if it is NOT a panic button.) Each time you open a zone, the internal sounder gives a pulsing tone. You cannot test the 'Tamper Circuits' without creating an alarm condition. Similarly, a panic button will always cause a full alarm. To stop walk test, key-in your access code. TO READ THE LOG The system keeps a log of the last ten alarm or tamper events. To read the log key in 8 then ENTER followed by your user code. The system switches on the zone or Tamper lights to show you the most recent event. If you want to see earlier events then press ‘<<‘ (the 1 key). To see more recent events press ‘>>’ (the 3 key). The keypad gives a short tone when you reach either end of the log. To leave the log press OMIT or ENTER. UK 496572 5 UK UK 6 Your Existing Code No. Followed by: The Code to be Changed. Two Bleeps from Sounder The New Four Digit Code Two Bleeps from Sounder TO CHANGE YOUR USER CODE Your system provides two separate four digit user codes. When the system is new, the user codes are “1234” and “0000”. Change the “1234” user code immediately to a number that only you know. The new code can be any four digit code you choose EXCEPT “0000”. The “0000” user code is inactive and will not operate the system. To activate the second user code change the “0000” to another four digit number. To inactivate the second user code again, change it back to “0000”. DO NOT use the same number for both user codes. . Entry Exit Zone: Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Zone 6: Installer Name: Day Tel: Night Tel: 6 496572 Francais Commandes et affichages L’affichage des fonctions suivantes est obtenu via les LEDS presentes sur la centrale et sur le(s) clavier(s) deporte(s) : a Allume en continu pour indiquer que le secteur est present. E Indique l’etat de la zone Entree/Sortie. 1 - 6 Indique l’etat des zones 1 a 6. T Allume en continu lorsque la boucle d’autoprotection est ouverte. S S'allume lorsque le systeme est a l'arret et clignote lorsqu'il est en Marche Partielle. Les touches suivantes sont presentes sur le clavier de la centrale ainsi que sur le clavier deporte 9427. O Mise en marche de la centrale avec isolation temporaire...

Other models in this manual:
Security Systems - 9448 (106.43 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category