Login:
Votes - 5, Average rating: 3.8 ( )

User manual JVC, model BR-DV3000E

Manafacture: JVC
File size: 1.47 mb
File name: 6147641d-4ace-4ae5-b6d7-5e60b9077667.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


INPUT SEL. SERIAL 9PIN WIRELESS LINE DV Y/C INPUT SEL. switch Backup unit: the main unit LIGHT ON OFF COUNTER CTL TC UB RESET OPERATE/WARNING MONITOR SELECT SHUTTER STATUS MENU FILTER 1 3200k 2 5600k 3 5600k+ND NG POWER GAIN OUTPUTWHT.BAL VTR ON OFF ALARM MONITOR SAVE STBY H M L BARS CAM AUTO KNEE PRST A B ONOFF CH-1 AUDIO CH-2 LEVEL AUTO IRIS LOLUX BACK L NORMAL SPOT L STRETCH NORMAL COMPRESS FULL AUTO BLACK DV cable DV terminal DV terminal Memo • Backup recording records the video and sound from the source unit to the main unit. While this unit is performing backup recording, please continue shooting from the source unit. • The audio mode is the mode configured in the source unit. (32k/48k) • Please set the BACKUP REC TIME item to OFF if the unit is not performing backup recording. Connection Connect the DV terminal of the source unit to the DV terminal of this unit with a DV cable. Setting up this unit Set the INPUT SEL. switch on the front panel to DV. Set the BACKUP REC TIME item of the SYSTEM (1/2) menu. Use the following settings according to the length of the tape of the source unit. For DV or mini DV cassettes: 25MIN : 30-minute tape 55MIN : 60-minute tape 75MIN : 80-minute tape 115MIN : 120-minute tape 175MIN : 180-minute tape 265MIN : 270-minute tape OFF : No backup recording Set the TC DUPLICATE item of the TIME CODE menu to OFF. • It records the data of the built-in time code generator or the built-in clock. • When the TC DUPLICATE menu item is set to AUTO or NON DROP, the time code of the DV camcorder will stop advancing. If the DV cable is disconnected, the time code of the backup recording will stop advancing. Operation 1. Recording begins on the source unit. * Please record from the beginning of the recording tape. 2. This unit begins recording when the tape of the source unit is near the end (about 5 minutes before the end of the tape). • This unit begins recording when the recording time of the source unit reaches the time configured by the BACKUP REC TIME setting. 41 RECORDING – Recording using the serial remote terminal – Recording can be turned ON/OFF with the serial remote controller or the footswitch connected to the SERIAL REMOTE terminal on the rear panel. Mini PROFESSIONAL SET MENIU EJECT REC PLAY PAUSE REW STOP FF DVCAM NTSC PAL REC INH. CH-1/3 CH-2/4 BR-DV3000 A.DUB OPERATE MIC REMOTE SEL. INPUT SEL. SERIAL 9PIN WIRELESS LINE DV Y/C DV IN/OUT AUDIO VIDEO CH 1/3 CH 2/4 LINE Y/C OUT IN REMOTE 9PIN SERIAL NTSC/PAL NTSC PAL DC12V REMOTE SEL. switch SERIAL REMOTE terminal • Serial remote controller: RM-G30 • Footswitch –––REMOTE[1/2]––– REMOTE ON LOCAL FUNCTION ALL KEYS PREROLL 5S REM FF /REW MODE FF / REW R EM S T O P S E L E E P B S T A R T D E L A Y O F S Y N C H R O N I Z A T I O N O N N E X T P A G E P A G E B A C K –––REMOTE[2/2]––– CONTROLLER SEL TYPE1 FOOT SWOF F PAGE BACK REMOTE (1/2) menu REMOTE (2/2) menu Memo • The serial remote controller can perform operations other than recording. • The buttons on the unit to be rendered operable can be set via the LOCAL FUNCTION item of the REMOTE( 1/2) menu. Connection Connect the serial remote controller (available separately: RM-G30) or the footswitch to the SERIAL REMOTE terminal on the rear panel. Setting Set the REMOTE SEL. switch on the front panel to SERIAL. Set the REMOTE item of the REMOTE (1/2) menu to ON. Set the FOOT SW item of the REMOTE (2/2) menu according to the way in which the serial remote terminal is used. OFF : Set to OFF when the serial remote controller is used. The footswitch cannot be used. L EDGE : Recording and recording pause operations are switched at the LOW edge of the footswitch signal. H EDGE : Recording and recording pause operations are switched at the HIGH edge of the footswitch signal. L LEVEL : Record at the LOW edge and pause recording at the HIGH edge of the footswitch signal. Operation Before using the footswitch, first engage the recording or recording pause mode via the buttons on the main unit. Memo • The footswitch can only be used for switching the recording operation ON/OFF. • The footswitch functions irrespectively of the REMOTE SEL switch settings. PLA YBACK – Connection/setting – This section explains the required connection, setting and operation method for using this unit as a player. Using this unit as a standalone device Monitor DV IN/OUT AUDIO VIDEOLINE Y/CCH 1/3 CH 2/4 INOUT REMOTE SERIAL9PIN NTSC/PAL NTSC PAL DC12V Y/C (S) video cable Video cable Audio cableAUDIO OUT VIDEO LINE OUT Y/C OUT Mini PROFESSIONALDVCAM NTSC PAL REC CH-1/3 CH-2/4 BR-DV3000 A.DUB OPERATE INPUT SEL. REMOTE SEL. MIC SERIAL WIRELESS9PIN LINE DV Y/C REMOTE SEL. switch SYSTEM (1/2) Menu ––– SYSTEM[ 1 / 2 ] ––– Connecting this unit to a video device with a DV terminal It can record with almost no loss in image or sound quality. DV cable (available separately) DV IN/OUT AUDIO VIDEO LINE Y/CCH 1/3 CH 2/4 INOUT REMOTE SERIAL9PIN NTSC/PAL NTSC PAL DC12V DV terminalDV terminal Player: the rear panel of the main ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category