Login:
Votes - 3, Average rating: 4.3 ( )

User manual Health O Meter, model PROFESSIONAL 597KL

Manafacture: Health O Meter
File size: 659.93 kb
File name: 597-599-752-manual.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


Please read this manual carefully and keep it handy for ready reference. Merci d’avoir achete ce produit. Veuillez lire attentivement ce manuel et le garder a portee de main pour pouvoir le consulter a tout moment Gracias por la adquisicion de este producto. Lea por favor este manual cuidadosamente y mantengalo a su alcance para una pronta referencia. ENGLISH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 FRANCAIS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ESPANOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TABLE OF CONTENTS CAUTION AND WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SCALE SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SET UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 OPERATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CALIBRATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 EXPLODED VIEW OF SCALE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CAUTION AND WARNING To prevent injury and damage to your scale, please follow these instructions very carefully • Do not transport the scale while the platform is loaded. • For accurate weighing the scale must be placed on a flat, stable surface. • For accurate weighing, verify proper operation according to the procedure described in this manual before each use. • Do not use in the presence of flammable materials. • Operating at other voltages and frequencies than specified could damage the equipment. • If the “LOW BAT” indicator activates, for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible. SPECIFICATIONS GENERAL Health o meter’s Digital Physician Scales, models 597KL, 599KL, 752KL use sophisticated microprocessor technology. Each precision instrument is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient. The scale is set up to determine the weight of a stationary patient. The weight can be displayed in pounds or in kilograms. The scale features a swivel display module which allows for viewing from either side of the scale. Also included with the 599KL and 597KL models are wheels for easy mobility. The unit can be operated using its AC adapter or by 6-C cell batteries (not included) SCALE SPECIFICATIONS Capacity and resolution 500lb x 0.2lb / 272kg x 0.1kg Power Requirements Adapter 120VAC – 6VDC – 60Hz or 6 – C cell 1.5 V batteries Environmental Operating temperatures: 50.F to 104.F Storage temperatures: 30.F to 125.F Humidity: 85% Platform Dimensions: 14 1.4" x 14 1.4" Scale Dimensions 597KL – Eye Level 14 1.4" x 22" x 54 3.4" 599KL – Waist-High 14 1.4" x 22" x 44 1.2" 752KL – Remote Display 14 1.4" x 14 1.4" 2 Set Up Tools Needed – 5mm Hex Driver, Phillips Screwdriver, Flat-Head Screwdriver (for 597KL height rod mount only) Materials Included – 4-Hex Head Machine Screws; 1-Phillips Screw (model 597and 599KL, 2 Phillips Screws (model 752KL); 1-Custom Height Rod Attachment Screw, for models 597 and 599; 1 AC adapter holder with 2 sheet-metal screws. 1. 2. Place batteries in battery holder at base of scale (if using battery operation – we recommend the use of EVEREADY Energizer® e2™ batteries). Feed load cell wire through pillar base. 4. 3. Screw in 4 hex screws with (5mm) hex driver. Insert pillar into pillar base Plug load cell wire into load cell plug in base of scale 5. 5. (see diagram 2a). The base of the scale has been designed to provide wire management for the load cell cable. See diagram 2b for wire management of load cell cable. Diagram 2a Diagram 2b 6. Set base upright 7. 8. Plug load cell wire into load cell plug in display module (correct For models 597KL and models 599KL, place display module on top of the plug is labeled load cell) pillar and use Phillips screw to tighten module to pillar. 3 9. For model 752KL, insert display module into wall mount/table top adapter. For wall mount place display module in adapter (see diagram 5a). For table-top place display module in adapter (see diagram 5b). Use 2 Phillips screws to secure the adapter to the display module. Diagram 5a Diagram 5a For model 597KL, insert height rod into pillar 10. base slot (see diagram 6a). Feed screw into hole. Use Flat-Head Screwdriver to tighten height rod to scale from the back (see diagram 6b). Diagram 6a Diagram 6b 11. 12. For ...

Other models in this manual:
Scales - PROFESSIONAL 599KL (659.93 kb)
Scales - PROFESSIONAL 752KL (659.93 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category