Login:
Votes - 3, Average rating: 4 ( )

User manual Rangemaster, model Chimney Hood

Manafacture: Rangemaster
File size: 1.1 mb
File name: c6dcf3e5-d33d-48cd-bf47-a02c7f0e72b0.pdf
Language of manual:itenfrdenl
Free link for this manual available at the bottom of the page



manual abstract


EN 10 CHARACTERISTICS Dimensions Components . . . Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2 1 Telescopic Chimney comprising: 2.1 1 Upper Section 2.2 1 Lower Section 8a 1 Right Air Outlet Grill 8b 1 Left Air Outlet Grill 9 1 Reducer Flange o 150-120 mm 10 1 Adapting ring o 120-125 mm 15 1 Air Outlet Connection Ref. Q.ty Installation Components 7.1 2 Hood Body Fixing Brackets . 7.2.1 2 Upper Chimney Section Fixing Brackets 11 8 Wall Plugs 12a 8 Screws 4.2 x 44,4 12c 6 Screws 2.9 x 9.5 12d 2 Screws M4 x 25 Q.ty Documentation 1 Instruction Manual EN 11 INSTALLATION Wall drilling and bracket fixing Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (height of the visible part of the panel) for installation with the back panel. • Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit, aligning the centre (notch) with the vertical reference line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line. • Mark the wall at the centres of the holes in the bracket. • Place bracket 7.1 as shown 109,5 mm from the vertical reference line and 190 mm above the horizontal reference line. • Mark the centres of the holes in the bracket. • Repeat this operation on the other side. REAR PANEL (OPTIONAL) The Rear Panel must be fitted before fixing the hood body and, if it is to be fixed at both top and bottom, must be fitted at the correct height prior to installing the bases. As this operation is rather complex, it should be carried out either by the kitchen installer or a qualified person who knows the final dimensions of the units. For fixing at the top only, proceed as follows: • Rest the back panel on the base, inserting the lower plate between the upper surface and the wall, centring it on the vertical reference line. • Mark the centres of the two holes in the upper plate. • Drill o 8 mm holes at all the centre points marked. • Insert the wall plugs 11 in the holes. • Fix the brackets using the 12a screws supplied. • Fix the back panel (where present) using the 12a screws supplied. EN 12 Mounting the hood body • Screw the two screws 12d supplied onto the brackets 7.1. • Hook the hood body onto the bracket 7.1, centring it around the vertical line. • Use the adjusting screws 12d underneath the hood to level the hood body. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe o 150 or 125 mm, the choice of which is left to the installer. • To install a o 125 mm air exhaust connection, insert the reducer flange 9 on the hood body air outlet and the adapting ring o120-125 10 on the reducer flange. • Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove any activated charcoal filters. RECIRCULATION VERSION AIR OUTLET • Push fit the air outlet fitting 15 onto the air outlet of the hood body. • Ensure that the activated charcoal filters have been inserted. EN 13 ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Chimney assembly Upper chimney section • Slightly widen the two sides of the upper chimney and hook . them behind the brackets 7.2.1, making sure that they are properly housed. • Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied. Lower chimney section • Slightly widen the two sides of the section and hook them between the upper section and the wall, making sure that they are properly housed. • Fix the sides of the bottom section to the hood body using the 2 screws 12c (2,9 x 9,5) supplied. • When installing the recirculation version, fit the directional grills 8a – 8b in their housings so that the directional symbols are at the top and towards the front of the hood. Ensure that they are inserted correctly in the outlet connection piece 15. EN 14 USE L Light Switches the lighting system on and off M Motor Switches the extractor motor on and off V Speed Sets the operating speed of the extractor: 1. Low speed, used for a continuous and silent air change in the presence of light cooking vapour. 2. Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio. 3. Maximum speed, used for eliminating the highest cooking vapour emission, including long periods. EN ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category