Login:
Votes - 4, Average rating: 4 ( )

User manual Creda, model TSF42K

Manafacture: Creda
File size: 871.42 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


The side panels have keyhole-shaped cutouts. Push the side bungs which blank off the charge control knob aperture, panels over the screws and push downwards. 20. Screw the side panels tightly (screw A). DO NOT OVERT1GH- 21. Fit the charge control knob and room thermostat control knob TEN THE SCREWS. Assembly is now finished. over their spindles in the right-hand side panel. 5 23. Finally, disconnect the electricity supply and connect each supply cable to a suitable double pole switch adjacent to the appliance. The heater Is now ready for operation and the supply may be reinstated. Important: Commlsioning heater - see overleaf. -■v Resetting the thermal cutout (when there has been a fault): This should only be done by a skilled person ! - Isolate the storage heater from the power supply - Remove the right-hand side panel -Allow the unit to cool down sufficiently - Press the reset button, e.g. using the blade of a screwdriver Circuit diagrams for Fan storage heaters Models TSF24K, TSF32K, TSF42K 1. Integral room thermostat (factory supplied) A1/Z1- A2/Z2- L1 L2 L3 LE LH M1 N R1 R2 R3 R7 R8 R9 RTR STR1,2 TB TR TR9 TRG Automatic charge control (not available in UK) Earth Live Thermostat controlled discharge supply Auxiliary heater supply Fan Neutral Heating elements Off peak (restricted) supply Single phase connection Off peak (restricted) supply Three phase connection Fan resistor (TSF42K only) Charge control resistor Auxiliary heater Room temperature contro Thermal cutout (automatic reset) Thermal cutout Charge control thermostat Temperature control, auxiliary heater Temperature control, air grille PE - PE On peak (24hour) supply 240 V~ 6 2. Wall mounted room thermostat (optional) A1/Z1~ A2/Z2- L1 L2 L3 LE LH M1 N R1 R2 R3 R7 R8 R9 RTR STR1,2 TB TR TR9 TRG Automatic charge control (not available in UK) Earth Live Thermostat controlled discharge supply Auxiliary heater supply Fan Neutral Heating elements Off peak (restricted) supply Off peak (restricted) supply Single phase connection Three phase connection 3L/N/Earth 415 V- Fan resistor (TSF42K only) Charge control resistor Auxiliary heater Room temperature control Thermal cutout (automatic reset) Thermal cutout Charge control thermostat Temperature control, auxiliary heater Temperature control, air grille PE N 8 \ N N — N 5 yj *r N — N N 4 ^ N L3 3 - L3 - L3 L2 — L 2 - L2 - L2 L1 1 ~ L1 - L1 PE - PE On peak (24hour) supply 240 V~ Commissioning Heater When all the installation work is complete, test heater for operation. Note: During initial operation some odour may be noticed due to the newness of the materials used in manufacture. This is normal and will disappear after a short period of use. It Is, however, advisable to keep the room will ventilated. It is also recommended that the fan is run to ensure that any dust particles that have accumulated In the heater are ejected. Clean the outlet grille and adjacent surfaces after first operation. In cases where unauthorised persons may tamper with the control knobs it is possible to remove the control knobs once the controls have been put to the correct setting, and fill the openings with the plastic caps supplied (see stage 18 overleaf). 7 459273.66.03 05/03/A Greda Applied Energy Products Limited Morley Way Telephone 01733 456789 Peterborough Facsimile 01733 310606 PE2 9JJ...

Other models in this manual:
Fans - TSF24K (871.42 kb)
Fans - TSF32K (871.42 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category