|
manual abstract
ceiling ceiling ceiling Page 3 Installation.. Installation.. Installation sequence; 1. Extractor unit / chimney brackets. 2. Top chimney duct 3. Bottom chimney duct • Carefully remove the extractor hood and the components from the packaging. • Remove the grease filters. CEILING MOUNTING TEMPLATE CEILING MOUNTING BRACKET POSITION CUT TEMPLATE TOP OF CEILING HOOD TEMPLATE LINE FROM CENTRE OF STOVE TO CEILING HORIZONTAL LINE 750 • Draw a fine vertical line on the wall from the rear-centre of the hob to the ceiling. • Draw another line, horizontal this time, where the bottom edge of the hood should be. (A minimum distance between the hob and the hood of 750mm is recommended.) • Take the template card and separate the ceiling mounting template from the hood mounting template by cutting along the indicated line. • Using masking tape, stick the ceiling mounting template to the wall directly below the ceiling and centered on the vertical line. • In a similar fashion stick the hood mounting template on the wall ensuring that the centre-lines line up with those drawn on the wall. • Note that the holes marked on the template cater for both 600mm and 900mm wide models. Please ensure that you only use those markings relating to the model you have purchased. Holes for Triangular 600 are marked with a (1). Holes for Triangular 900 are marked with a (2). Holes not marked are common to all models. • For mounting the chimney brackets, drill 6 holes, 5mm in diameter and 45mm deep into the wall as indicated on the mounting template. • For mounting the extractor hood, drill 4 holes, 8mm in diameter and 60mm deep as indicated on the mounting template. • Once all the holes have been drilled the templates must be removed. • Push the 5mm Dia. wall plugs through the holes in the chimney mounting brackets. Insert the plugs into the drilled holes together with the chimney mounting bracket and fasten securely. • Push the 8mm Dia. wall plugs into the 8mm Dia. holes ensuring that they are flush with the wall. • Partially screw two 6mm Dia. screws into the two top wall plugs leaving them to protrude about 10mm. • Lift and hook the extractor hood over and onto the two protruding screws through the key-hole slots provided at the top of the extractor hood frame. • Insert the other two 6mm Dia. screws through the holes inside the extractor hood housing and into the 8mm Dia wall plugs. • Align the extractor hood with the centre and horizontal lines before tightening all four 6mm screws. Page 4 Before fitting the chimneys, connect up the outlet ducting (if required) and insert the fitted plug into the wall socket. • Remove the protective film from the chimney ducting taking care not to damage the polished stainless steel surface. • Fit the upper chimney duct section (the one with louvre outlets) to the ceiling mounting bracket using the screws supplied. CEILING MOUNTING BRACKET TOP CHIMNEY DUCT • The lower duct fits over the extractor hood motor assembly and over the upper duct. Take care not to scratch or damage the hood and upper duct surfaces. • Loosely attach the lower duct bottom edge to the hood by four self tapping screws through four holes on the inside of the extractor hood . INSERT 6 SELF TAPPING SCREWS • Fit the lower chimney duct to the lower wall mounting bracketand tighten the six screws on the inside of the extractor hood • Drill 3.5mm Dia. holes through the top holes in the bottom chimney and through the lower end of the top chimney duct. • Fasten the two chimneys to the centre chimney bracket. Top chimney duct Drill two 3.5mm Diameter holes and secure two chimney ducts to mounting bracket. Mounting bracket Bottom chimney duct Page 5 Grease filters. Grease filters. • Remove the plastic outer protective lining on the grease filters before fitting them to the extractor hood. • To fit the filters, engage the two lugs at the rear of each filter into the rectangular slots of the extractor hood frame, lift the filter and press the handle catch inwards . • Engage the filter and release the catch. • To remove the filter, for cleaning purposes, reverse the procedure described above. Optional Carbon pad filters. • Carbon pad filters assist in removing any unwanted cooking odours from the atmosphere. • If your installation ducts filtered air to the outside, the carbon pad filters are not required. • Should you require them, factory approved, carbon pad filters and installation kits may be purchased from your nearest Defy service Centre or their authorised agents. STEEL ROD REMOVED STEEL ROD IN PLACE GREASE FILTER CARBON PAD FILTER Page 6 Glass cover Retaining ring Light bulb Glass cover Retaining ring Light bulb Operation. • Select the fan speed you require. Motor speed • Push button ‘3’ for high extraction level. Off button • Push button ‘2’ for medium. • Push button ‘1’ for lo...
Other models in this manual:Fans - DCH260 (295.29 kb)
Fans - DCH284 (295.29 kb)
Fans - DCH285 (295.29 kb)