|
manual abstract
If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area apply a bi-polar switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over- current category III, in accordance with installation instructions. IMPORTANT: Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled. 63 Before beginning installation • In addition check whether near the installation area of the hood (in the area accessible also with the hood mounted) an electric connection to the mains is available and if it is possible to connect a fumes discharge device to the outside (Extraction mode only). • Warning! Do not connect the appliance to the mains until the installation is fully complete. • Install the electronic box with 2 screws (a-b-c). Fig. 6 Fig. 6a Fig. 6b Fig. 6c Installation • Remove the grease filters. • Drawing a line on the wall with a pencil up to the ceiling, corresponding to the centre line, will make the installation operations easier. Fig. 7 • Apply the perforation diagram to the wall: the vertical centre line printed on the perforation diagram should correspond to the centre line drawn on the wall. In addition, the lower edge of the perforation diagram corresponds to the lower edge of the hood. Fig. 8 Fig. 8 Fig. 7 • Make holes as indicated on the template, insert the wall dowels and screw 2 screws into the upper holes, leaving a space of about 1 cm between the head of the screw and the wall. Fig9a-b Note: Always make the holes indicated on the template. The upper 2 are for hooking the hood up while the lower holes (generally 2 lateral) are for the definitive and safety fixing. Fig. 9a Fig. 9b 65 • Apply flues support bracket to the wall touching the ceiling. Use the flues support bracket as a perforation diagram (the small slot in the support must coincide with the line previously drawn on the wall, if present), and mark two holes with a pencil. Make the holes and insert 2 dowels. • Fix the flues support bracket to the wall with 2 screws. Fig. 10 Fig. 10 Fig. 11 • Hang the hood to the 2 upper screws. • Introduce and screw the screws (and washers) up into the holes for the definitive fixing (COMPULSORY!!). Then, having checked the setting of the hood, TIGHTEN ALL THE upper and lower SCREWS. Fig. 11 Note: the lower fixing points are visible removing the grease filters and they are at the sides of the hood 66 Fig. 12a Fig. 12b Fig. 12c Fig. 13a Fig. 13b • Connect a tube (tube and bands for fixing not supplied, to be purchased) for discharging the fumes to the connection ring placed over the aspiration motor unit. The other end of the tube should be connected to a device for expelling fumes on the outside of the hood in the asp...
Other models in this manual:Fans - DK 4360 (2.99 mb)
Fans - DK 4390 (2.99 mb)
Fans - DK 4360 (2.99 mb)
Fans - DK 4360 (2.99 mb)