Login:
Votes - 2, Average rating: 3.5 ( )

User manual Rangemaster, model RMHDT90SS

Manafacture: Rangemaster
File size: 1.21 mb
File name: 4ac9e622-3176-475d-b690-66735525e1db.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


• Never leave frying pans unattended during use as overheated fats and oils might catch fire. • Never do flambe cooking under this cooker hood. • Do not leave naked flames under the cooker hood. 2 IMPORTANT SAFETY INFORMATION • MAINTENANCE AND SERVICE • This appliance can be a hazard if the grease filters and charcoal filters are not cleaned and replaced as recommended. • Always insist on genuine RANGEmaster spare parts. • The halogen light and cover lamp might hot. • Under no circumstances should you attempt to repair the appliance yourself. Repairs carried out by inexperienced persons may cause injury or more serious malfunction. In the event of your chimney hood requiring service contact: RANGEmaster Helpline: 0845 603 5312, or Consumer Services: 0870 789 5107 3 OPERATING INSTRUCTIONS YOUR APPLIANCE OPERATING INSTRUCTIONS YOUR APPLIANCE The chimney hood is designed to extract BUTTON V1 - Turns the fan On and Off at unpleasant odours from the kitchen, it will the low speed setting. This is not extract steam. The appliance can be an ideal speed when cooking installed to recirculate or extract for long periods as the continuous flow of air is contaminated air. particularly quiet. COOKER HOOD CONTROLS BUTTON V2 -Second speed, suitable for The chimney hood functions are controlled most normal operating by four push buttons located centrally on conditions. This speed gives the front of the canopy. an excellent ratio between . treated air when the hood is recirculated and the level of noise. BUTTON V3 -Third speed, suitable for removing strong odours when frying or simmering for long periods. . . BUTTON L -Turns the worktop lighting On and Off. 4 OPERATING INSTRUCTIONS TO OPERATE Select the required fan speed and light if required. To obtain the best performance when cooking it is advisable to switch the chimney hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing. RECIRCULATION In the recirculation mode contaminated air enters the chimney hood through the grease filter cassettes. The air is cleaned as it passes through the (optional) charcoal filter and is passed out through grilles in either side of the chimney stack into the kitchen. EXTRACTION In the extraction mode contaminated air enters the chimney hood through the grease filter cassettes and is passed out through ducting into the atmosphere. When used in the ducting mode the charcoal filter is not required. Never do flambe cooking under this chimney hood. When using a gas hob under this chimney hood never leave the burners uncovered while the hood is in use or when the pans have been removed. The grease filters and the charcoal filter should be cleaned and replaced as recommended or more frequently if the hood is used consistently over 4 hours per day. 5 MAINTENANCE AND CLEANING Regular maintenance and cleaning will ensure good performance and reliability, while extending the working life of the hood. Special attention should be paid to the grease filter cassettes and the charcoal filter when the hood is used in the recirculation mode. Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply. METAL GREASE FILTERS The grease filters absorb grease and dust during cooking to help keep the chimney hood clean inside, and should be cleaned every month with normal usage or more frequently if the hood is used consistently over 4 hours per day. Remove the metal grease filter cassettes one at a time, by pressing the release catch towards the rear of the hood as illustrated opposite. When replacing the filters ensure that the handle faces forwards. The metal grease filters can be washed in a dishwasher or by hand using a mild detergent or liquid soap. CHARCOAL FILTER In the recirculation mode the activated charcoal filter absorbs smells and unwanted odours. The charcoal filter cannot be cleaned or regenerated and must be replaced every four months, or more frequently if the hood is used consistently over 4 hours per day. To replace the charcoal filter, first remove the metal grease filters and press against the plastic retaining clips to remove the charcoal filter as illustrated opposite. We recommend that you wear rubber gloves when removing the charcoal filter as the filter will be saturated in grease. Put the filter into a polythene bag or container so that the grease and dirt cannot spill onto clothing of furnishing. THIS APPLIANCE CAN BE A POSSIBLE FIRE HAZARD IF THE GREASE FILTERS ARE NOT CLEANED AND THE CHARCOAL FILTERS REPLACED AS RECOMMENDED. Replacement charcoal filters may be purchased by returning the enclosed order form, or by telephoning 01803 296155 if you wish to pay by credit card. 6 MAINTENANCE AND CLEANING LIGHTING The canopy is fitted with two 20W halogen spotlamps. WARNING! The halogen light and cover lamp might hot. If one of the spotlamps fails to function check that the two pins are correctly inserted into the lamp holder. To replace a spotlamp remo...

Other models in this manual:
Fans - RMHDT110SS (1.21 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category