|
manual abstract
13. Connect to the power supply and switch on the power using switch/socket outside the canopy hood. 14. Slide the upper chimney piece up to the ceiling and secure in place with four screws supplied. INSTALLATION – RECIRCULATED For recirculation do not cut the 170mm hole into the ceiling and purchase the charcoal filters and recirculation kit 1744. The recirculation kit must be used to channel the air to the top of the flue. For other accessories parts and service please contact your local supplier or approved service agent. MAINTENANCE The manufacturer is not liable for any damage caused by not following these instructions. Particular care must be taken with the grease filters which must be periodically cleaned (at least every two months). Remove the grease filters and wash them either by hand in hot soapy water or in the dishwasher using mild detergent. Note: some discolouration of the frame may occur. Caution: Never use abrasive or oil based liquid cleaners. To clean the stainless steel and glass components of the canopy hood use mild detergent and warm water. In areas of high humidity and coastal environments cleaning should be carried out frequently. For accessories, parts and service, please contact your local supplier (refer to the warranty certificate). LIGHT REPLACEMENT (Halogen bulb 12 Volts/20 Watt) 1. Switch off the power to the canopy hood. 2. Use a small bladed screwdriver to prise off the light cover taking care not to damage the surrounding material. 3. Remove the defective bulb from the canopy hood. 4. Replace with a new bulb using a cloth. Do not touch the bulb with fingers. 5. Snap the cover back into place. WARNINGS • This canopy hood is not intended for use by young children or infirm persons without supervision. • Young children should be supervised to ensure that they do not play with the canopy hood. • There shall be adequate ventilation of the room when the canopy hood is used at the same time as appliances burning gas or other fuels. (A partial vacuum in the room could result in too high a concentration of gas in the air). • You must read the details concerning the method and frequency of cleaning. • There is a fire risk if cleaning is not carried out in accordance with the instructions. • Do not flambe under the canopy hood. • Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances burning gas or other fuels. • The minimum distance between the hob surface and the filters of the canopy hood shall be 600mm (650mm if installed over a gas hob). • Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is fulfilled. • If the supply cord of this equipment is damaged it must only be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard. Electrical Rating: 310W (1.28 A) Max at 240V 50Hz Manufactured for By: Robinhood Ltd 6 Zelanian Drive, East Tamaki Auckland, New Zealand ISO9001 Certified 104923 issue A ECN 06 037 ...
Other models in this manual:Fans - 80327 EC120DXV1 (187.59 kb)
Fans - 88833 EC120DXV2 (187.59 kb)
Fans - 80328 EC120DMV1 (187.59 kb)