Manafacture: Miele
File size: 938.4 kb
File name: 75ed6dda-ddfc-49bd-b3f3-fe98d8527598.pdf
|
manual abstract
^ After cleaning, the filters can be placed on a towel to air dry. ^ While the filters are removed, clean any dirt or grease from the filter casing to prevent the risk of fire. When putting the grease filters back make sure that the locking clips are visible facing down towards the cooking surface. If a filter is incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing. ^ After returning the grease filters, press the grease filter button for 3 seconds to reset the timer. The indicator light will go out. ^ If the grease filters are cleaned before the timer has reached its maximum, the grease filter button should be pressed for 6 seconds to reset the counter to zero. Cleaning and Care Active charcoal filters In recirculation mode two active charcoal filters must be used in addition to the grease filters. The charcoal filters are designed to absorb cooking odors. Replacement active charcoal filters can be ordered from the Miele Technical Service Department. USA 1-800-999-1360 CDN 1-800-565-6435 Please quote part # 03 284 681. ^ ^ After replacing the charcoal filters, press and hold the charcoal filter button for about 3 seconds to reset the charcoal filter timer. The indicator light will go out. If the charcoal filters are replaced before the timer has reached its maximum, the charcoal filter button should be pressed for 6 seconds to reset the counter to zero. ^ Remove the grease filters to access the charcoal filters. Follow the instructions supplied with the active charcoal filters. Replace the active charcoal filters when the charcoal filter indicator lights. Replace the filters at least every 6 months or when they no longer absorb odors efficiently. Cleaning and Care Changing the light bulb Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to cool. Do not touch the bulb surface. Fingerprints or body oils deposited on the bulb will decrease the life of the bulb. Follow the bulb manufacturer’s instructions. ^ To change the halogen bulb first remove the lamp cover, a. ^ Pull the bulb, b, out of its socket and replace with a new one. ^ Return the lamp cover, a. Never use the lighting without the lamp cover, a, in place. The glass is specially made to filter harmful light rays. After Sales Service In the event of a fault which you cannot correct yourself please contact the Miele Technical Service Department : U 1-800-999-1360 techserv@mieleusa.com V 1-800-565-6435 service@miele.ca When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filter is removed. Installation Instructions 22 Caring for the environment Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. To prevent suffocation of children, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of their reach. Disposal of an old appliance Old appliances may contain materials that can be recycled. Please contact your local recycling authority about the possibility of recycling these materials. Before discarding an old hood, unplug it from the outlet and cut off its power cord to prevent hazards. Installation accessories 24 Installation accessories a 2 recirculation vents (recirculation mode only) b 2 protective shields prevent scratches to the chimney during installation. c 1 protective shield prevents scratches from the canopy during installation. d 1 diverter (recirculation mode only) e 1 flex hose for connecting the diverter to the exhaust connection. f 2 hose clips for securing the ducting. g 1 reducing collar for use with 5" (125 mm) exhaust ducting. h 1 non-return flap for vented air extraction only. i Upper retaining plate B secures the chimney extension. j Middle retaining plate C for additional stability of the chimney. k Lower retaining plate A secures the canopy and motor assembly. 12 large headed screws 5 x 40 mm for securing the retaining plates and the canopy. (S8 wall anchors included in the packaging are not for use in USA / CDN.) 2 M 6 locking nuts for securing the motor assembly. 4 screws 3.9 x 7.5 mm for securing the chimney and the chimney extension CAUTION: During the installation process please be careful of sharp edges that can cause harm. Plywood backing The majority of the weight of the installed ventilation system will be supported by retaining plate A. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. 1/2" (13 mm) thick) spanning at least two studs must...
Other models in this manual:Fans - DA211 (938.4 kb)