|
manual abstract
The air outlet must under no cir. cumstances be connected to ventilation ducts for rooms i. which fuel-burning appliances are installed. l It is advisable to apply for authorization from the relevan. controlling authority when connecting the outlet to a. unused chimney flue or combustion gas duct. The air outlet installation must comply with th. regulations laid down by the relevant authorities. l When the unit is used in its extractor version, . sufficiently large ventilation hole must be provided, wit. dimensions that are approximately the same as the outle. hole. l National and regional building regulations impose . number of restrictions on using hoods and fuel-burnin. appliances connected to a chimney, such as coal or oi. room-heaters and gas fires, in the same room. l The national decree on fuel-burning systems specifies . maximum depression of 0.04 bar in such rooms. l Hoods can only be used safely with appliances connecte. to a chimney if the room and/or flat (air/environmen. combination) is ventilated from outside using a suitabl. ventilation hole approximately 500-600 cm2 large t. avoid the possibility of a depression being created durin. operation of the hood. If you have any doubts, contact the relevant controllin. authority or building inspector.s office. l Since the rule for rooms with fuel burning appliances i. .outlet hole of the same size as the ventilation hole., . hole of 500-600 cm2, which is to say a larger hole, coul. reduce the performance of the extractor hood. l If the hood is used in its filtering function, it will operat. simply and safely in the above conditions without th. need for any of the aforementioned measures. l When the hood is used in its extractor function, th. following rules must be followed to obtain optima. operation. . short and straight outlet hos. . keep bends in outlet hose to a minimu. . never install the hoses with an acute angle, they mus. always follow a gentle curve onl. . keep the hose as large as possible (120 mm O min.). l Failure to observe these basic rules will drastically reduc. the performance and increase the noise levels of th. extractor hood. Installation - Fig. . . lllll Put the template onto the wall (1) and drill two O12mm holes (2). . lllll Fit two hooks (3) on the drilled holes. . lllll Hang the hood on the hooks and adjust the position of the hoo. using the two screws on the bottom of the hooks (5). . lllll Remove the metal filters (4) and mark two points (6). Remove th. hood and drill two O8mm holes on the marked points. Fit two O8mm wall dowels (7), Hang again the hood and fix th. hood definitively with two screws 5X45 (8). . lllll Fix the chimney support (10) with two screws 5 x 45 mm (9) an. two wall dowels (11) on the wall close to the ceiling. . lllll For exhausting version: Fit the connection ring (S) on the top o. the hood with two screws O 3,5 x 6,5 mm (12S) then fit a. axhausting pipe long enough to reach the outside (13S). For recycling version: Fix definitively the d...
Other models in this manual:Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 825 D (194.09 kb)
Fans - DUNSTABZUGSHAUBE 8259 S (194.09 kb)