Login:
Votes - 3, Average rating: 5 ( )

User manual Hunter Fan, model 42947-01

Manafacture: Hunter Fan
File size: 5.55 mb
File name: 42947.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 5. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 6. Acceptable for use over a bathtub or shower when connected to a GfCI protected branch circuit. 7. Install fan at least 5 feet (1.52 m) above the floor. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded. 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty. 2. Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 5. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 6. Acceptable for use over a bathtub or shower when connected to a GfCI protected branch circuit. 7. Install fan at least 5 feet (1.52 m) above the floor. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded. C A U T I O N W A R N I N G 1. for general ventilating use only. Do not use for ventilating hazardous or explosive materials. DISCONNECT 2. To avoid motor bearing damage and noisy/unbal- ELECTRIC anced impellers, keep drywall spray, construction dust, etc. off power unit. pOWER SUppLY 3. DO NOT install this product in a wall. This prod- AND LOCK OUT uct is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point SERVICE pANEL upward. BEfORE 4. please read specification label on product for fur- SERVICING UNIT ther information and requirements. pREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN fAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL pARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 42947-01 01/12/2007 3 1 Turn off the power source. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation x2 3/8” Cable Connector H I J K L x4 * * * NOTE:Strain relief cable connector must be installed. Not Included. A B C 95261-01-000 74508-03-133 96382-01-262 75184-01-133 97250-01-437 M 76075-01-437 x2 D Extra Screws E F G 95047-05-000 75864-02-000 03242-07-133 Check all the parts. If damaged, call 1-888-830-1326 for replacements. 2 E I Loosen screws. NOTE: Remove all packing materials before installation. 42947-01 01/12/2007 Included. 5 4 7 G 8 F Remove the motor/blower from the housing. 4 H E 3 Remove the pre-loaded screw tip covers. Remove the wiring cover screw. 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 42947-01 01/12/2007 9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction 5 10 B C Choose Installation Option For New Construction go to step A11, page 5 For Existing Construction go to step B11, page 8 A1 E 5/8 1/2 5/8 1/2 A2 Screw pre-loaded screws into joist or framing. 42947-01 01/12/2007 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A4 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A3 Route wires through the strain relief. Connect wires as shown. 0 A6 Connect 4” duct and vent to the outside. Tape joints. If ducting does...

Other models in this manual:
Fans - 82020 (5.55 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category