Login:
Votes - 1, Average rating: 3 ( )

User manual Hunter Fan, model LA STRADA 82022

Manafacture: Hunter Fan
File size: 12.53 mb
File name: 42929.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


7. Install fan at least 5 feet (1.52 m) above the floor. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded. E F G H I J M N O x4 * * * NOTE:Strain relief cable connector must be installed. Not Included. A B C 95044-01-096 95029-01-000 77481-01-000 03242-01-232 95491-06-000 74508-03-133 97258-01-000 65219-01-000 77521-01-000 75184-01-092 97260-01-000 P 76079-02-481 x2 D Extra Screws K L 3/8” Cable Connector 3 1 Turn off the power source. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. 2 F J Loosen screws. NOTE: Remove all packing materials before installation. 42929-01 10/26/2010 5 4 7 H 8 G Remove the motor/blower from the housing. 4 3 I F Remove the pre-loaded screw tip covers. Remove the wiring cover screw. 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 42929-01 10/26/2010 9 F Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction - attaching to joist 5 10 B C Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 A11 F 5/8 1/2 5/8 1/2 A12 Screw pre-loaded screws into joist or framing. 42929-01 10/26/2010 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A14 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A13 Route wires through the strain relief. Connect wires as shown. A016 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. 6 A15 F H Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 42929-01 10/26/2010 A19 J Secure the motor by tightening the 2 screws. A20 Turn on the power source. 7 Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. A17 0 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 0 I A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 E1 Go to step on page 17 to attach grille. 42929-01 10/26/2010 Slide the mounting rails into brackets. Mark position of screws by using holes as a template. Insert screws, leaving space between the screw head and the joist. Screws are not provided. New Construction – suspended between joists 8 B11 E F 5/8 5/8 1/2 1/2 B12 1/8” bit B14 B15 F B13 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. Attach the rails onto the screws. B16 42929-01 10/26/2010 Tighten screws. Route wires through the strain relief. Connect wires as shown. 9 B17 B18 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B19 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option B21 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. G H B20 42929-01 10/26/2010 10 B27 E1 Go to step on page 17 to attach grille. B22 I Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. I B23 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 Turn on the power source. ON OFF B26 Test the motor. If the motor does not run, check the plug connection. B24 J Secure the motor by tightening the 2 screws. 42929-01 10/26/2010 C11 EXISTING FAN C12 E F Existing Construction – accessible from above 11 NO EXISTING FAN 8” 8 1/2” OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8 1/2”). Cut out an opening for the housing. Use the motor housing as a template to mark position. Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. 5/8 5/8 1/2 1/2 C13 C14 Mark position of screws by using holes as a template. 42929-01 10/26/2010 C17 C18 C19 C20 12 C15 C16 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the s...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category