|
manual abstract
If an attic is above ceiling level a 7DVAIS (Attic Insulation Shield) must be installed. The enlarged ends of the vent section always face downward. (Fig. 32) 18 10007852 19 LDVT Series Direct Vent GaS Fireplace 10007852 Vertical Restrictor Plate 36LDVT, 39LDVT, 43LDVT When installing the 36LDVT, 39LDVT or 43LDVT with a vertical through-the-roof configuration flue system, the restrictor plate (#10008048) supplied with the appliance MUST BE FITTED TO THE APPLIANCE at the installation. NOTE: Do not use the restrictor plate supplied with the vertical termination cap. 1. Remove the rear log support. Save the two (2) screws. 2. Remove the two (2) nuts and save them. 3. Place the restrictor plate (Fig. 34) and secure it with the two (2) nuts. 4. Replace the rear log support to the same location as before and secure it with the screws removed in Step 1. ............ ................................ ........ Rear Log Support Restrictor Plate FP1555 Fig. 34 Assembling the restrictor plate. LDVT Series Direct Vent Gas Fireplace Venting Components 7TDVRVT - Through the wall Rear Vent Termination Starter Kit Model 7TDVSK - Sidewall Venting (Twist Lock Pipe) Model 7FDVSK - Sidewall Venting (Flex Vent Pipe) Models 7TDVTK/TV - Hot Touch Termination Kits Model 7TDVTVTK/TV - Cool Touch Termination Kit Starter Kit - Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSKV-F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS -Snorkel Kit (Twist Lock Pipe) Model 7FDVSKS -Snorkel Kit (Flex Vent Pipe) 584B Vent componentsStarter Kit 2/25/99 djt Starter Pipe Model 7TDVP 20/8 - 24” Starter Pipe Bulk Model 7FDVP 30/8 - 30” Flex Pipe Bulk 45o Elbow 7TDV45 for Rear Vent to Vertical Vent or Vertical/Horizontal Offsets 90o Transition Elbow 7TDVRT90 for Rear Vent to Vertical Vent 90° Elbow 7TDV90 Vertical/Horizontal Offset Telescopic vent sections 7TDVP1117 -11” to 17” adjustable length 7TDVP3567 -35” to 67” adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8” -4 per box Model 7TDVP12” -4 per box Model 7TDVP24” -4 per box Model 7TDVP36” Model 7TDVP48” Firestop Spacer Model 7DVFS Attic Insulation Shield Model 7DVAIS Vertical/Horizontal Combination Offset Support Model 7DVCS 20 10007852 LDVT Series Direct Vent GaS Fireplace Operating Instructions Glass Information 6. Tilt the glass frame out slightly at the bottom, lift the frame up and away from the fireplace. Only glass approved by CFM Corporation 7. To replace the glass frame reverse the procedure. should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass front removed, cracked or broken. • Replacement glass (complete with frame window) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person. Lower Clamps The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 35) The lower access door is hinged along the bottom edge and is folded down to Louvre Removal ........................................................................................................................................................................................................ 1. 2. Louvre Glass Panel FP1227 allow access Window Frame Assembly Removal Fig. 35 Remove top louvre assembly. 1. Turn the fireplace OFF (including the pilot) 2. If the unit has been operating allow time for the components to cool. 3. Remove the top louvre assembly. 4. Open the lower louvre panel. 5. Release the two clamps securing the lower edge of the frame by pulling down on the handles. (Fig. 36) Window Frame As- sembly Pull Clamp HookPush Clamp Handle Window Frame Assembly FP1228 Fig. 36 Window frame assembly removal. Glass Cleaning It is necessary to periodically clean the glass. During start-up condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia based household cleaner and warm water (We recommend gas fireplace glass cleaner) within the first few weeks of operation. After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house. Clean the glass after the first two weeks of operation. Do not clean glass when hot. Do not use abrasive cleaners. Do not strike or slam glass. 10007852 21 LDVT Series Direct Vent Gas Fireplace Installation of Logs, Lava Rock & Ember Material The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children and dispose of the materi...
Other models in this manual:Fans - 36LDVT 39LDVT (3.87 mb)
Fans - 3LDVT (3.87 mb)