For fan dimensions, (other countries). specific requirements. see Fig. A. If there is damage to the fitted lead Exhaust air must not be discharged 2. Attach the ducting over the inlets and this must be replaced by the into a flue used for exhausting outlet and secure it with worm manufacturer or service agent. fumes from appliances supplied drive clips. If you have any queries before with energy other than electric. installing these products or after they Requirements of all authorities Connecting ConnectingConnecting the thethe fan fanfan are installed, call the concerned must be observed for Xpelair Technical Hotline +44 (0) 8709 1. Switch off the mains electrical supply exhaust air discharge. 000430. Our engineers are there to and remove fuses. When installed for use in possible help during normal office 2. Wire the fan as shown in fig. B. chemical corrosive atmospheres, hours (UK only) and may be faxed at 3. Connect the cable from the isolating consult our Technical Service all other times on +44 (0) 8709 000530. switch to the electrical supply wiring. Department. (For overseas markets Customers outside the UK please 4. Refit fuse before turning on the contact your local Xpelair contact your local Xpelair distributor, electricity supply. Distributor). details of which are available Note: For fixed wiring circuits, the The inlet grilles should be situated from the UK office. protective fuse for the appliance must at least 0.5m distance from the not exceed 5A. discharge outlet of a flued heating or cooking appliance. Description Connecting ConnectingConnecting the thethe fan fanfan Xplus 275 1. The fan can be operated using the 3 speed when used with an appropriate Position of the fan controller (not supplied). The fan has Extract only. controller (not supplied). 3 speed settings: High(H), Medium (M) and Low (L) . The fan can be mounted to a suitably Suitable for continuous operation. strong wall or roof member. What WhatWhat the thethe inst instinstaller alleraller will willwill need needneed Position of the air outlet Cleaning A means for disconnection in all poles At least 0.5m away from open door or 1. Before cleaning isolate completely from must be incorporated in the fixed wiring in window, or the inlet of another ventilation the mains supply. accordance with the wiring regulations. device. 2. Wipe the inlet covers carefully with Speed controller. a damp cloth. Suitably rated cable. 3. Dry thoroughly. Ducting long enough to connect from the 4. Never use solvents to clean. position of the air intake positions of the Apart from cleaning, no other air outlet via the fan. maintenance is required. Ducting accessories, including internal and external grilles and fasteners. For flexible ducting, you will need worm drive clips (available from Xpelair) to attach the ducting to the fan inlets and outlet. If installing in a position where condensation is likely to run back towards the fan, you will need a suitable condensation trap. A B N L DOUBLE POLE ISOLATING SWITCH FUSE L M H GREEN/YELLOW BLUE BROWN LOW SPEED MEDIUMSPEEDHIGH SPEED Link to obtain speeds as follows L = Low Speed L - M = Medium Speed L - H = High Speed BLACK BLACK/WHITE CABLE FITTED TO FAN LINK WIRES. CONNECT TO OBTAIN REQUIRED SPEED Xplus 275 WIRING INSTRUCTIONS N P P N L SWITCH TERMINALS DOUBLE POLE ISOLATING SWITCH FUSE P T2 T3 T1 GREEN/YELLOW BLUE BROWN BLACK BLACK/WHITE L M H Xplus 275 WIRED THROUGH THE THREE SPEED SWITCH REF.91457AW N CABLE FITTED TO FAN ...
Other models in this manual:Fans - 275 (70.65 kb)