User manual Viking, model DEV1200

Manafacture: Viking
File size: 211.19 kb
File name: m2290301_DEV1200.pdf
Language of manual:enfr
Free link for this manual available at the bottom of the page



manual abstract


READ AND SAVE THESE INSTRUCTIONS MODEL DEV1200 EXTERIOR MOUNTED VENTILATOR FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND DCIH RANGE HOODS. 30" TO 66" WIDE, 9" TO 18" HIGH. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer or your distributor. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. WARNING 5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce risk of fire, use only metal ductwork. 8. This unit must be grounded. CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum. Blower Dimensions 22 x 30.828 x 12.724 SPECIFICATIONS MODEL VOLTS AMPS CFM DUCT SIZE DEV1200 120 3.0 1200 10" DIA. PLAN THE INSTALLATION ALL INSTALLATIONS 1. Locate the ventilator so the length of the duct run and number of elbows needed are kept to a minimum. 2. Where possible, ventilator should be centered between wall studs or roof rafters. 3. Avoid pipes, wires, or other ductwork that may be running through the wall. TYPICAL ROOF MOUNTED INSTALLATION TYPICAL WALL MOUNTED INSTALLATION MODEL DEV1200 EXTERIOR VENTILATOR 10" ROUND DUCT SOFFIT WALL HOOD CANOPY (island canopy available) MODEL DEV1200 EXTERIOR VENTILATOR 10" ROUND DUCT SOFFIT 10" ROUND ELBOW WALL HOOD CANOPY (island canopy available) INSTALLER: Leave This Manual With The Homeowner HOMEOWNER: Use And Care Information On Page 4 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1. Locate the ventilator on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, electrical lines, etc.). If the ventilator top is level with the roof peak, it will not be seen from the street. Keep this approximate location in mind as you work from within the attic. 2. Mark and drill a guide hole centered between roof rafters. 11" dia. hole20." 11" dia. hole 1" OO 911/16" 20." OO 15" 913/16" 18" 1211/16" 1." dia. hole1." dia. hole Roof RafterRoof RafterRoof Rafter REMOVE SHINGLESREMOVE SHINGLES Roof Rafter Guide hole(centeredbetween rafters) Guide hole (centered between rafters) 1211/16" 18" 3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 913/16" to the left of the guide hole, then up 1211/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectangular cutout (18" W x 20." H) and remove only the shingles in this area. C. Mark an 11" diameter hole centered on the guide hole. Cut this hole through the roof board(s). D. Mark and cut a 1." diameter hole through the roof board(s) where shown. 22" 2" 7" 29-1/2" 2" 1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening area. 2. From inside, mark and drill a guide hole centered between wall studs. 11" dia. holeGuide hole(centered between studs) 22" 29." 1411/16" 111113/16" Wall StudWall Stud11" dia. hole 17" 1." dia. hole1." dia. hole 3" OO O REMOVESIDINGREMOVE SIDING Guide hole (centered between studs) 3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 1113/16" to the left of the guide hole, then up 1411/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectangular cutout (22" W x 29." H) and remove only the siding in this area. C. Mark an 11" diameter hole centered on the guide hole. Cut this hole through the roof board(s). D. Mark and ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category