Manafacture: Wolf Appliance Company
File size: 212.31 kb
File name: 2c3a2af9-99ac-0894-35c9-3b746e730148.pdf
|
manual abstract
24" (610) classic stainless steel Specifications are subject to change without notice. duct covers Horizontal discharge kit Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator sectionofourwebsite,wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Planning Information Pro 24"(610) Deep Wall Ventilation Hood MODEL PW602418(R) INSTALLATION SPECIFICATIONS 30" TO 36" (762 – 914) T O COUNTER T OP 30" TO 36" (762 – 914) T O COUNTER T OP 24" ( 610 ) DEPTH OF HOOD NOTE: 24" (610) deep wall hoods can be vertical or horizontal discharge. DIMENSIONS Overall Width of Hood 60" (1524) Overall Height of Hood 18" (457) Overall Depth of Hood (excluding rail) 24" (610) Countertop to Bottom of Hood 30" (762) to 36" (914) Location of Electrical Within shaded area See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. 4 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW602418(R) INSTALLATION NOTES Refer to the illustrations and specifications for overall dimensions and installation specifics. Wolf Pro wall ventilation hoods are recommended for use with any Wolf cooking appliance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side. IMPORTANT NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle. Installation of all Pro ventilation hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration on page 4. Wolf Pro wall hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for Pro ventilation recommendations and blower options. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro wall hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance.com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW602418(R) DUCTING CONSIDERATIONS Wolf Pro 24" (610) deep wall hoods are shipped without the blower assembly. Internal, in-line and remote blower assemblies are available. IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower. Pro 24" (610) deep wall hoods have a vertical discharge. A horizontal discharge kit is available as a sales accessory. The hood will operate most efficiently when ductwork does not exceed 50' (15 m) in length. Local building codes may require the use of make-up air. Consult your local HVAC professional for specific requirements in your area. IMPORTANT NOTE: Wolf Pro 24" (610) deep wall hoods must be vented to the outside. Use only metal ductwork. Refer to the illustration below for ducting considerations for Pro 24" (610) deep wall hoods. Ducting for Pro 24" (610) deep wall hoods. DUCTWORK INSTALLATION THROUGH ROOF 24" (610) DEPTH OF HOOD ROOF CAP OR REMOTE BLOWER 10" (254) ROUND DUCT SOFFIT OR CABINET OR DUCT COVER NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT. VERTICAL DISCHARGE TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES) 30" TO 36" (762–914) COUNTERTOP TO BOTTOM OF VENTILATION HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 18" (457) HEIGHT OF HOOD WALL HOOD Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Planning Information Pro 24" (610) Deep Wall Ventilation Hood MODEL PW602418(R) WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. Wolf ventilation hoods are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. Internal, in-line and remote blower assemblies are available as sales accessories through your Wolf dealer. IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products. 113/4" (298) 211/2" (546) 243/8"...
Other models in this manual:Fans - PW602418(R) (212.31 kb)