16). Defective lamps must only be replaced by lamps of the same type (Cool Beam)! You can obtain the original spare part (No. 03602611) from trade dealers or via Gaggenau after-sales service. Inserting the lamp – Insert the lamp and turn it to the right. – Screw down the lamp cover again. – Connect the appliance to the mains again. 5. Maintenance Fig. 16 Fig. 15 6. Assembly instructions 6.1 Technical data Weight: 28 kg Dimensions: 898 x 520 mm Electrical connection Pay attention to the rating plate data. The mains connecting cable must at least correspond to the type H 05 VV-F G 0,75. When replacing the mains cable, you must dismantle the tubular connection piece (undo 2 screws). The appliance must only be connected by an authorised specialist. The specialist is responsible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with reference to the operating instructions. He must explain to the user how the appliance can be isolated from the mains whenever required. Connection possibilities The extractor hood was conceived for the exhaust air or air recirculation mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall. The connector of the connecting cable is connected to the socket that is located behind the duct cover on the wall. If this is not possible, it must be possible to isolate all poles of the appliance from the mains by way of the domestic fuse, or by means of accessible isolating device with a contact gap of at least 3 mm. AH 600-190 FD xxxx xxxx AC 220-240V 50Hz 345W xxxx 160W 35W 3x50W 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm. The wall hood was conceived for the exhaust air or air recirculation mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall. It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement. Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation. During the course of planning, a chimney sweep must be consulted if a room air-dependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode. Adequate incoming air must be ensured. The applicable construction and safety regulations must be observed. Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed. Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means. Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and – there are no cross-sectional constrictions in the upward direction (this reduces the volume flow). As standard, the blow-out opening of the wall hood is in the upward direction. To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box Exhaust air operation Depending on the ceiling height, the following duct units are at your disposal for exhaust air operation: – LK 600-010: Ventilation duct for a ceiling height of 2.27 to 2.60 m – LK 600-020: Ventilation duct for a ceiling height of 2.61 - 3.00 m The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood. If required, a side outlet for the air duct is available at an extra charge. The socket must be place behind the duct cover on the wall. 260 Suspension TM 150-045 (O 150). Note: To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed 522.5 in the exhaust air line. The condensate separator 520 must still be acciessible after installation. Air recirculation You need the following accessories to install the air recirculation hood: – KF 600-090: activated charcoal filter: Depending on the ceiling height, the following duct units are a...