|
manual abstract
! WARNING Do not install or use fan if any part is damaged or missing. Call Toll-Free: 1-800-654-3545 This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage. ! WARNING ! WARNING This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Up to 50 ft. 14 50-100 ft. 12 A J E D C F B K N I L H G M How to Put Your Ceiling Fan Together 1. Remove the fan motor and housing assembly from the styrofoam packaging and position it so that the top of the motor is facing you. 2. Remove the hanger ball from the downrod by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 8. HANGER BALL DOWNRODPIN SETSCREW Figure 1 3. Separate, untwist and unkink the three motor leads. Route the motor leads through the downrod and seat the downrod in the motor coupling (Figure 2). DOWNROD MOTOR COUPLING HAIRPIN CLIP SETSCREW CLEVIS PIN CLEVIS PIN MOTOR LEADS SETSCREW MOTOR COUPLING DOWNRODHAIRPIN CLIP Figure 2 4. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). (Pin and clip are supplied in loose parts bag.) The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull the hanger ball to make sure the clevis pin is properly installed. WARNING ! It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 2) could result in the fan falling. 5. Install the setscrew (supplied) in the motor coupling (Figure 2). While pulling up on the downrod, tighten the setscrew using the setscrew wrench (supplied). NOTE: The setscrews must be properly installed as described above, or fan wobble could result. 6. Screw two 1” threaded studs (supplied) into the motor (Figure 3). Leave approximately 7/8” of the stud extending above the motor. Coil the wires and wire connectors around the motor coupling then slide the motor cover over the downrod and rotate the cover until the threaded studs protrude. Install two lockwashers(supplied) to secure the cover to the motor. All wires and wire connectors must be enclosed under the motor cover. 1" THREADED MOTOR COVER MOTOR COUPLINGKNURLED KNOB (2) LOCKWASHER (2) STUD (2) Figure 3 NOTE: Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor. 7. Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 4). CEILING COVER Figure 4 DOWNROD PIN HANGER BALL 4 8. Reinstall the hanger ball on the downrod (Figure 4) as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod. Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin in captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. 11. Use three 10-32 x 8mm slotted Phillips button head screws to secure the fan blade to the lower blade flange (Figure 7). (Refer to IMPORTANT note above step 10.) Repeat the procedure for the remaining four lower blades. 10-32 x 8mm PHILLIPS BUTTON HEAD SCREWS (3) WARNING ! It is critical that the pin in the hanger ball is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling. 9. The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. IMPORTANT: When installing the fan blades on the blade flanges, be sure the short side of the fan blade is oriented with the blade flange as shown in Figure 5. SHORT SIDE OF FAN BLADE BLADE FLANGE Figure 5 10. Use three 10-32 x 8mm Phillips button head screws to secure the fan blade to the upper blade flange (Figure 6). (Re...
Other models in this manual:Fans - CF2800WB (334.84 kb)
Fans - CF2800PW (334.84 kb)