Login:
Votes - 5, Average rating: 4 ( )

User manual Cisco Systems, model PVC2300

Manafacture: Cisco Systems
File size: 4.42 mb
File name: CameraAccessoriesFINAL.pdf
Language of manual:enfrda
Free link for this manual available at the bottom of the page



manual abstract


STEP 3 Set up and focus your camera before placing it in the enclosure. When it is in the enclosure, you can’t make any more adjustments. Refer to the PVC2300 and WVC2300 Administration Guide for setup instructions. NOTE The Cisco WVC2300 camera must be wired to be used in the enclosure. Wireless mode is not supported. Camera Accessories Installation and Administration Guide Accessory Installation Processes Installing the PVC2300/WVC2300 Cameras in a VC 020 Enclosure Preparing the Enclosure STEP 1 Use the provided wrench to remove the four screws that attach the enclosure cover to the base. STEP 2 Lift the enclosure cover off the base. STEP 3 Use the provided wrench to release the four keyhole screws, then slide the camera platform to withdraw it from the enclosure base. STEP 4 Use the supplied L-type hex wrench to detach the rectangular support from the camera platform. The rectangular support is required only during shipping. Camera Accessories Installation and Administration Guide Accessory Installation Processes Installing the PVC2300/WVC2300 Cameras in a VC 020 Enclosure Preparing the Brackets This procedure describes how to connect the mounting bracket and the enclosure bracket. STEP 1 Using the L-type hex wrench, adjust the ball joint in the enclosure bracket to set the approximate direction the enclosure. STEP 2 Place the wall mount bracket and the enclosure bracket together. STEP 3 Screw the brackets together using the provided stainless steel screw and L-type hex wrench. Connecting the Cables Before completing this procedure, you must cut the camera’s Ethernet cable and the power cord as it will be necessary to feed them through the mounting brackets and the cable conduits found on the bottom of the enclosure. WARNING Equipment connected to outdoor cameras must be permanently grounded in accordance with national and local codes. Statement 374 WARNING Hazardous voltages may be present in the outdoor camera cables under fault conditions. Disconnect all cables from the outdoor cameras before servicing this equipment. Statement 376 WARNING Do not use this product near water; for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement, or near a swimming pool. Statement 1035 WARNING Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. Statement 1036 Camera Accessories Installation and Administration Guide Accessory Installation Processes Installing the PVC2300/WVC2300 Cameras in a VC 020 Enclosure WARNING Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. Statement 1037 WARNING Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. Statement 1038 STEP 1 Feed the cut Ethernet cable and power cord through the brackets. STEP 2 Feed the Ethernet cable and power cord through the conduits found on the bottom of the enclosure. The power cord goes through the conduit closest to the power supply wiring. WARNING When stranded wiring is required, use approved wiring terminations, such as closed-loop or spade-type with upturned lugs. These terminations should be the appropriate size for the wires and should clamp both the insulation and conductor. Statement 1002 WARNING Use copper conductors only. Statement 1025 Camera Accessories Installation and Administration Guide Accessory Installation Processes Installing the PVC2300/WVC2300 Cameras in a VC 020 Enclosure STEP 3 Add the ferrite core on the power cord. STEP 4 Add the ferrite core on the Ethernet cable. Camera Accessories Installation and Administration Guide Accessory Installation Processes Installing the PVC2300/WVC2300 Cameras in a VC 020 Enclosure STEP 5 Connect the power cord to the terminal block assembly. You can make these connections in one of two ways: color matching the wires, or using a multimeter to measure resistance from the power cord and the terminal block assembly. WARNING This equipment has been designed for connection to TN and IT power systems. Statement 1007 WARNING This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 WARNING When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 WARNING Use copper conductors only. Statement 1025 WARNING The ground connection from the power cable MUST connect to the chassis first. The power cord ground wire must connect to the chassis ground terminal first. A closed loop connector must be attached to the ground and then attached to the screw and lock washer at the protective earth ground (PE). Camera Accessories Installation and Administration Guide Accessor...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category